» Articles » PMID: 21792056

An Increase in Aortic Blood Flow After an Infusion of 100 Ml Colloid over 1 Minute Can Predict Fluid Responsiveness: the Mini-fluid Challenge Study

Overview
Journal Anesthesiology
Specialty Anesthesiology
Date 2011 Jul 28
PMID 21792056
Citations 91
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Predicting fluid responsiveness remains a difficult question in hemodynamically unstable patients. The author's objective was to test whether noninvasive assessment by transthoracic echocardiography of subaortic velocity time index (VTI) variation after a low volume of fluid infusion (100 ml hydroxyethyl starch) can predict fluid responsiveness.

Methods: Thirty-nine critically ill ventilated and sedated patients with acute circulatory failure were prospectively studied. Subaortic VTI was measured by transthoracic echocardiography before fluid infusion (baseline), after 100 ml hydroxyethyl starch infusion over 1 min, and after an additional infusion of 400 ml hydroxyethyl starch over 14 min. The authors measured the variation of VTI after 100 ml fluid (ΔVTI 100) for each patient. Receiver operating characteristic curves were generated for (ΔVTI 100). When available, receiver operating characteristic curves also were generated for pulse pressure variation and central venous pressure.

Results: After 500 ml volume expansion, VTI increased ≥ 15% in 21 patients (54%) defined as responders. ΔVTI 100 ≥ 10% predicted fluid responsiveness with a sensitivity and specificity of 95% and 78%, respectively. The area under the receiver operating characteristic curves of ΔVTI 100 was 0.92 (95% CI: 0.78-0.98). In 29 patients, pulse pressure variation and central venous pressure also were available. In this subgroup of patients, the area under the receiver operating characteristic curves for ΔVTI 100, pulse pressure variation, and central venous pressure were 0.90 (95% CI: 0.74-0.98, P < 0.05), 0.55 (95% CI: 0.35-0.73, NS), and 0.61 (95% CI: 0.41-0.79, NS), respectively.

Conclusion: In patients with low volume mechanical ventilation and acute circulatory failure, ΔVTI 100 accurately predicts fluid responsiveness.

Citing Articles

Assessing fluid responsiveness by using functional hemodynamic tests in critically ill patients: a narrative review and a profile-based clinical guide.

Messina A, Grieco D, Alicino V, Matronola G, Brunati A, Antonelli M J Clin Monit Comput. 2025; .

PMID: 39831948 DOI: 10.1007/s10877-024-01255-x.


Automated and reference methods for the calculation of left ventricular outflow tract velocity time integral or ejection fraction by non-cardiologists: a systematic review on the agreement of the two methods.

Gonzalez F, Zawadka M, Varudo R, Messina S, Caruso A, Santonocito C J Clin Monit Comput. 2024; .

PMID: 39729150 DOI: 10.1007/s10877-024-01259-7.


Passive leg raising test versus rapid fluid challenge in critically ill medical patients.

Majunke N, Philipp D, Weidhase L, Pasieka B, Kunz K, Seidel F Med Klin Intensivmed Notfmed. 2024; .

PMID: 39240330 DOI: 10.1007/s00063-024-01176-2.


Using echocardiography to predict fluid-responsiveness and manage the need for fluids.

Vieillard-Baron A, Boissier F, Slama M Intensive Care Med. 2024; 50(7):1137-1142.

PMID: 38748267 DOI: 10.1007/s00134-024-07407-6.


Easy method to determine fluid responsiveness in septic shock patients: end-tidal CO2 - a prospective observational study.

Ozkarakas H, Ucar O, Tekgul Z, Ozmuk O, Ozturk M, Bilgin M Ulus Travma Acil Cerrahi Derg. 2024; 30(2):90-96.

PMID: 38305657 PMC: 10977503. DOI: 10.14744/tjtes.2024.37309.