» Articles » PMID: 21788148

Dependencies of Multi-component T2 and T1ρ Relaxation on the Anisotropy of Collagen Fibrils in Bovine Nasal Cartilage

Overview
Journal J Magn Reson
Publisher Elsevier
Date 2011 Jul 27
PMID 21788148
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Both NMR spectroscopy and MRI were used to investigate the dependencies of multi-component T2 and T1ρ relaxation on the anisotropy of bovine nasal cartilage (BNC). The non-negative least square (NNLS) method and the multi-exponential fitting method were used to analyze all experimental data. When the collagen fibrils in nasal cartilage were oriented at the magic angle (55°) to the magnetic field B0, both T2 and T1ρ were single component, regardless of the spin-lock field strength or the echo spacing time in the pulse sequences. When the collagen fibrils in nasal cartilage were oriented at 0° to B0, both T2 and T1ρ at a spin-lock field of 500 Hz had two components. When the spin-lock field was increased to 1000 Hz or higher, T1ρ relaxation in nasal cartilage became a single component, even when the specimen orientation was 0°. These results demonstrate that the specimen orientation must be considered for any multi-component analysis, even for nasal cartilage that is commonly considered homogenously structured. Since the rapidly and slowly relaxing components can be attributed to different portions of the water population in tissue, the ability to resolve different relaxation components could be used to quantitatively examine individual molecular components in connective tissues.

Citing Articles

First in-vivo magic angle directional imaging using dedicated low-field MRI.

Ristic M, Chappell K, Lanz H, McGinley J, Gupte C, Amiras D Magn Reson Med. 2024; 93(3):1077-1089.

PMID: 39428680 PMC: 11680723. DOI: 10.1002/mrm.30332.


Ultrafast - NMR for Correlating Different Motional Regimes of Molecules.

Tolkkinen K, Mankinen O, Mailhiot S, Telkki V Anal Chem. 2024; 96(42):16534-16542.

PMID: 39383336 PMC: 11503516. DOI: 10.1021/acs.analchem.4c00513.


Bi-Exponential 3D UTE-T1ρ Relaxation Mapping of Ex Vivo Human Knee Patellar Tendon at 3T.

Malhi B, Moazamian D, Shin S, Athertya J, Silva L, Jerban S Bioengineering (Basel). 2024; 11(1).

PMID: 38247943 PMC: 10813751. DOI: 10.3390/bioengineering11010066.


Whole knee joint mapping using a phase modulated UTE adiabatic T (PM-UTE-AdiabT ) sequence.

Ma Y, Carl M, Tang Q, Moazamian D, Athertya J, Jang H Magn Reson Med. 2023; 91(3):896-910.

PMID: 37755319 PMC: 10843531. DOI: 10.1002/mrm.29871.


SPICY: a method for single scan rotating frame relaxometry.

Tolkkinen K, Mailhiot S, Selent A, Mankinen O, Henschel H, Nieminen M Phys Chem Chem Phys. 2023; 25(18):13164-13169.

PMID: 37129427 PMC: 10171246. DOI: 10.1039/d2cp05988f.


References
1.
Qian Y, Williams A, Chu C, Boada F . Multicomponent T2* mapping of knee cartilage: technical feasibility ex vivo. Magn Reson Med. 2010; 64(5):1426-31. PMC: 2965791. DOI: 10.1002/mrm.22450. View

2.
Mlynarik V . Magic angle effect in articular cartilage. AJR Am J Roentgenol. 2002; 178(5):1287; author reply 1287-8. DOI: 10.2214/ajr.178.5.1781287. View

3.
Bolbos R, Link T, Ma C, Majumdar S, Li X . T1rho relaxation time of the meniscus and its relationship with T1rho of adjacent cartilage in knees with acute ACL injuries at 3 T. Osteoarthritis Cartilage. 2008; 17(1):12-8. PMC: 2838771. DOI: 10.1016/j.joca.2008.05.016. View

4.
Reiter D, Lin P, Fishbein K, Spencer R . Multicomponent T2 relaxation analysis in cartilage. Magn Reson Med. 2009; 61(4):803-9. PMC: 2711212. DOI: 10.1002/mrm.21926. View

5.
Richmon J, Sage A, Wong W, Chen A, Sah R, Watson D . Compressive biomechanical properties of human nasal septal cartilage. Am J Rhinol. 2006; 20(5):496-501. DOI: 10.2500/ajr.2006.20.2932. View