» Articles » PMID: 15508163

Reduction of Residual Dipolar Interaction in Cartilage by Spin-lock Technique

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2004 Oct 28
PMID 15508163
Citations 69
Authors
Affiliations
Soon will be listed here.
Abstract

The influence of radiofrequency (RF) spin-lock pulse on the laminar appearance of articular cartilage in MR images was investigated. Spin-lock MRI experiments were performed on bovine cartilage plugs on a 4.7 Tesla small-bore MRI scanner, and on human knee cartilage in vivo on a 1.5 Tesla clinical scanner. When the normal to the surface of cartilage was parallel to B0, a typical laminar appearance was exhibited in T2-weighted images of cartilage plugs, but was absent in T1rho-weighted images of the same plugs. At the "magic angle" orientation (when the normal to the surface of cartilage was 54.7 degrees with respect to B0), neither the T2 nor the T1rho images demonstrated laminae. At the same time, T1rho values were greater than T2 at both orientations throughout the cartilage. T1rho dispersion (i.e., the dependence of the relaxation rate on the spin-lock frequency omega1) was observed, which reached a steady-state value of close to 2 kHz in both parallel and magic-angle orientations. These results suggest that residual dipolar interaction from motionally-restricted water and relaxation processes, such as chemical exchange, contribute to T1rho dispersion in cartilage. Further, one can reduce the laminar appearance in human articular cartilage by applying spin-lock RF pulses, which may lead to a more accurate diagnosis of degenerative changes in cartilage.

Citing Articles

Orientation-independent quantification of macromolecular proton fraction in tissues with suppression of residual dipolar coupling.

Gao Z, Yu Z, Zhou Z, Hou J, Jiang B, Ong M NMR Biomed. 2024; 38(1):e5293.

PMID: 39535330 PMC: 11602536. DOI: 10.1002/nbm.5293.


Quantitative and Compositional MRI of the Articular Cartilage: A Narrative Review.

Albano D, Viglino U, Esposito F, Rizzo A, Messina C, Gitto S Tomography. 2024; 10(7):949-969.

PMID: 39058044 PMC: 11280587. DOI: 10.3390/tomography10070072.


Quantitative MRI methods for the assessment of structure, composition, and function of musculoskeletal tissues in basic research and preclinical applications.

Casula V, Kajabi A MAGMA. 2024; 37(6):949-967.

PMID: 38904746 PMC: 11582218. DOI: 10.1007/s10334-024-01174-7.


T1rho MR properties of human patellar cartilage: correlation with indentation stiffness and biochemical contents.

Bae W, Statum S, Masuda K, Chung C Skeletal Radiol. 2023; 53(4):649-656.

PMID: 37740079 PMC: 11542609. DOI: 10.1007/s00256-023-04458-6.


Correction of errors in estimates of T at low spin-lock amplitudes in the presence of B and B inhomogeneities.

Zu Z, Adelnia F, Harkins K, Wang F, Ostenson J, Gore J NMR Biomed. 2023; :e4951.

PMID: 37070215 PMC: 10619883. DOI: 10.1002/nbm.4951.