» Articles » PMID: 21566688

A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots

Overview
Date 2011 May 14
PMID 21566688
Citations 76
Authors
Affiliations
Soon will be listed here.
Abstract

Continuum robots, which are composed of multiple concentric, precurved elastic tubes, can provide dexterity at diameters equivalent to standard surgical needles. Recent mechanics-based models of these "active cannulas" are able to accurately describe the curve of the robot in free space, given the preformed tube curves and the linear and angular positions of the tube bases. However, in practical applications, where the active cannula must interact with its environment or apply controlled forces, a model that accounts for deformation under external loading is required. In this paper, we apply geometrically exact rod theory to produce a forward kinematic model that accurately describes large deflections due to a general collection of externally applied point and/or distributed wrench loads. This model accommodates arbitrarily many tubes, with each having a general preshaped curve. It also describes the independent torsional deformation of the individual tubes. Experimental results are provided for both point and distributed loads. Average tip error under load was 2.91 mm (1.5%-3% of total robot length), which is similar to the accuracy of existing free-space models.

Citing Articles

Quasi-static Path Planning for Continuum Robots By Sampling on Implicit Manifold.

Wang Y, Chen Y IEEE Int Conf Robot Autom. 2025; 2024:8728-8734.

PMID: 39995850 PMC: 11848831. DOI: 10.1109/icra57147.2024.10611372.


Bayesian Optimization Based Preprocedural Planning For Robotic Left Atrial Appendage Occlusion.

Hao R, Itsarachaiyot Y, Cavusoglu M Int Symp Med Robot. 2024; 2024.

PMID: 39628872 PMC: 11611301. DOI: 10.1109/ismr63436.2024.10585608.


Unified Shape and External Load State Estimation for Continuum Robots.

Ferguson J, Rucker D, Webster 3rd R IEEE Trans Robot. 2024; 40:1813-1827.

PMID: 39464302 PMC: 11500828. DOI: 10.1109/tro.2024.3360950.


Teleoperation and Contact Detection of a Waterjet-Actuated Soft Continuum Manipulator for Low-Cost Gastroscopy.

Campisano F, Remirez A, Landewee C, Calo S, Obstein K, Webster 3rd R IEEE Robot Autom Lett. 2024; 5(4):6427-6434.

PMID: 39156224 PMC: 11328976. DOI: 10.1109/lra.2020.3013900.


Toward Extending Concentric Tube Robot Kinematics for Large Clearance and Impulse Curvature.

Zhang Z, Shen J, Ha J, Chen Y IEEE Robot Autom Lett. 2024; 9(3):2407-2414.

PMID: 38912312 PMC: 11189652. DOI: 10.1109/lra.2024.3351000.


References
1.
Rucker D, Webster Iii R . Parsimonious evaluation of concentric-tube continuum robot equilibrium conformation. IEEE Trans Biomed Eng. 2009; 56(9):2308-11. DOI: 10.1109/TBME.2009.2025135. View

2.
Dupont P, Lock J, Itkowitz B, Butler E . Design and Control of Concentric-Tube Robots. IEEE Trans Robot. 2011; 26(2):209-225. PMC: 3022350. DOI: 10.1109/TRO.2009.2035740. View

3.
Arun K, Huang T, Blostein S . Least-squares fitting of two 3-d point sets. IEEE Trans Pattern Anal Mach Intell. 2011; 9(5):698-700. DOI: 10.1109/tpami.1987.4767965. View

4.
Rucker D, Webster 3rd R, Chirikjian G, Cowan N . Equilibrium Conformations of Concentric-tube Continuum Robots. Int J Rob Res. 2014; 29(10):1263-1280. PMC: 4129649. DOI: 10.1177/0278364910367543. View