» Articles » PMID: 21503854

Accuracy of Invisalign® Treatments in the Anterior Tooth Region. First Results

Overview
Journal J Orofac Orthop
Specialty Dentistry
Date 2011 Apr 20
PMID 21503854
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: To analyse (a) to what extent the pretreatment model at the beginning of the treatment corresponds to the initial position in the ClinCheck® and (b) to what extent the predicted treatment result corresponds to the actual result of the therapy at the end of the treatment.

Material And Methods: Pre- and posttreatment models as well as the initial and final position of the ClinCheck with a total of 35 patients aged between 15 and 59 were measured; all of whom were treated by using the Invisalign® technology (Invisalign®, Align Technology, S.C., Calif., USA). The measurement of the initial and final models was conducted by using an electronic digital calliper rule, i.e. that of ClinCheck® using the measurement tool ToothMeasure® of Invisalign® Software. The following parameters in the anterior region were measured: Overjet, Overbite, dental midline shift.

Results: Pretreament models and the initial ClinChecks® revealed slight deviations in the parameters overjet 0.08 mm (standard deviation (SD) 0.3), overbite 0.3 mm (SD 0.4) and dental midline deviation 0.1mm (SD 0.4). The final model and the final ClinCheck® revealed larger deviations: the differences for the Overjet were on average 0.4 mm (SD 0.7), Overbite 0.9 mm (SD 0.9) and dental midline shift 0.4 mm (SD 0.5).

Conclusions: The IT-based transmission of mal-aligned teeth into the ClinCheck® presentation provides sufficiently good accuracy. Tooth corrections in the vertical plane were more difficult to realize. A vertical overcorrection in the final ClinCheck®, a case refinement at the end of the treatment or additional measures (e.g. horizontal beveled attachments or vertical elastics) seems useful to achieve the individually intended therapeutic goal.

Citing Articles

Diagnostic performance of ClinCheck, Dolphin Imaging, and 3D Slicer software for Bolton discrepancy analysis.

Teixeira Santana T, Copello F, Maranon-Vasquez G, Issamu Nojima L, Franzotti SantAnna E Angle Orthod. 2024; 95(1):51-56.

PMID: 39317378 PMC: 11662356. DOI: 10.2319/022724-156.1.


Civil liability of orthodontists and aligner manufacturers in the treatment with orthodontic aligners.

Pinheiro I, Guedes C, Apolinario A, Faria F, Mota Junior S, Phiton M Dental Press J Orthod. 2024; 29(1):e24spe1.

PMID: 38359315 PMC: 10871073. DOI: 10.1590/2177-6709.29.1.e24spe1.


Effects of different patterns of movement for correcting a deep curve of Spee with clear aligners on the anterior teeth: a finite element analysis.

Zhu L, Liu L, Wang W, Deng W BMC Oral Health. 2024; 24(1):217.

PMID: 38341537 PMC: 10859030. DOI: 10.1186/s12903-024-03906-6.


Assessment of Awareness and Perceptions of Healthcare Professional Graduates Regarding the Use of Clear Aligners in Orthodontic Treatment.

Shivlani V, Niranjane P, Paul P Cureus. 2023; 15(10):e46348.

PMID: 37920637 PMC: 10618842. DOI: 10.7759/cureus.46348.


Predicted and achieved overjet and overbite measurements with the Invisalign appliance: a retrospective study.

Meade M, Weir T Angle Orthod. 2023; 94(1):3-9.

PMID: 37839803 PMC: 10928945. DOI: 10.2319/030923-161.1.


References
1.
Boyd R . Surgical-orthodontic treatment of two skeletal Class III patients with Invisalign and fixed appliances. J Clin Orthod. 2005; 39(4):245-58. View

2.
Meier B, Wiemer K, Miethke R . Invisalign--patient profiling. Analysis of a prospective survey. J Orofac Orthop. 2003; 64(5):352-8. DOI: 10.1007/s00056-003-0301-z. View

3.
Wheeler T . Invisalign material studies. Am J Orthod Dentofacial Orthop. 2004; 125(3):19A. DOI: 10.1016/j.ajodo.2004.01.010. View

4.
Kravitz N, Kusnoto B, Agran B, Viana G . Influence of attachments and interproximal reduction on the accuracy of canine rotation with Invisalign. A prospective clinical study. Angle Orthod. 2008; 78(4):682-7. DOI: 10.2319/0003-3219(2008)078[0682:IOAAIR]2.0.CO;2. View

5.
Boyd R . Complex orthodontic treatment using a new protocol for the Invisalign appliance. J Clin Orthod. 2007; 41(9):525-47. View