Structural Conformation and Leaching from in Vitro Aged and Retrieved Invisalign Appliances

Overview
Publisher Elsevier
Specialty Dentistry
Date 2004 Dec 14
PMID 15592222
Citations 46
Authors
Affiliations
Soon will be listed here.
Abstract

The objectives of this study were to investigate the structure of Invisalign appliances (Align Technology, Santa Clara, Calif) after intraoral exposure, and to qualitatively and quantitatively characterize the substances leached from the aligners after accelerated in vitro aging. Samples of Invisalign appliances were randomly selected from 10 patients before intraoral placement and after retrieval, and the prepared specimens were subjected to (1) bright-field optical reflection microscopy to study the surface morphology; (2) Fourier transform infrared microspectroscopy to characterize the in vivo changes in molecular composition induced on appliance surfaces, (3) scanning electron microscopy and energy dispersive X-ray microanalysis to identify the elemental composition of integuments formed on the surface, and (4) Vickers hardness (HV 200) testing. Another set of reference and retrieved appliances was subjected to artificial aging for 2 weeks, and the extracts were subjected to gas chromatography-mass spectroscopy. The retrieved appliances demonstrated substantial morphological variation relative to the as-received specimens involving abrasion at the cusp tips, adsorption of integuments, and localized calcification of the precipitated biofilm at stagnation sites. Buccal segments of retrieved appliances showed an increase in hardness, which might be attributed to mastication-induced cold work; however, the clinical implication of this effect on mechanotherapy is unknown. In vitro aged and retrieved appliances were found to leach no traceable amount of substances in an ethanol aging solution.

Citing Articles

The effect of bleaching agent on the compressive strength of orthodontic thermoplastic retainer materials.

Ehteshami A, Omidi S, Ghasemi M Dent Res J (Isfahan). 2025; 22:2.

PMID: 40028506 PMC: 11870327. DOI: 10.4103/drj.drj_216_24.


Orthodontic Treatment with Fixed Appliances Versus Aligners: An Experimental Study of Periodontal Aspects.

Giannini L, Galbiati G, Tartaglia F, Grecolini M, Maspero C, Biagi R Dent J (Basel). 2025; 13(2).

PMID: 39996944 PMC: 11853974. DOI: 10.3390/dj13020070.


Experimental assessment of damage and microplastic release during cyclic loading of clear aligners.

Barile C, Cianci C, Paramsamy Kannan V, Pappalettera G, Pappalettere C, Casavola C PLoS One. 2025; 20(2):e0318207.

PMID: 39908302 PMC: 11798498. DOI: 10.1371/journal.pone.0318207.


Assessment the thermoforming effect on the physical and mechanical properties of different thermoplastic orthodontic retainers: An study.

Hamid D, Al-Khatieeb M J Orthod Sci. 2025; 13:41.

PMID: 39758108 PMC: 11698246. DOI: 10.4103/jos.jos_61_24.


Mechanical characterization and structural analysis of elastodontic appliances under intraoral and artificial aging conditions.

Cui Y, Huang T, Yu Z, Zhou S, Zhang L, Han Y BMC Oral Health. 2024; 24(1):1337.

PMID: 39487402 PMC: 11529478. DOI: 10.1186/s12903-024-05101-z.