» Articles » PMID: 21472556

Determination of the Deuterium Abundances in Water from 156 to 10,000 Ppm by SIFT-MS

Overview
Specialty Chemistry
Date 2011 Apr 8
PMID 21472556
Authors
Affiliations
Soon will be listed here.
Abstract

In response to a need for the measurement of the deuterium (D) abundance in water and aqueous liquids exceeding those previously recommended when using flowing afterglow mass spectrometry (FA-MS) and selected ion flow tube mass spectrometry (SIFT-MS) (i.e. 1000 parts per million, ppm), we have developed the theory of equilibrium isotopic composition of the product ions on which these analytical methods are based to encompass much higher abundances of D in water up to 10,000 ppm (equivalent to 1%). This has involved an understanding of the number density distributions of the H, D, (16)O, (17)O and (18)O isotopes in the isotopologues of H(3)O(+)(H(2)O)(3) hydrated ions (i.e. H(9)O (4) (+) cluster ions) at mass-to-charge ratios (m/z) of 73, 74 and 75, the relative ion number densities of which represent the basis of FA-MS and SIFT-MS analyses of D abundance. Specifically, an extended theory has been developed that accounts for the inclusion of D atoms in the m/z 75 ions, which increasingly occurs as D abundance in the water is increased, and which is used as a reference signal for the m/z 74 ions in the measurement of D abundance. In order to investigate the efficacy of this theory, experimental measurements of deuterium abundance in standard mixtures were made by the SIFT-MS technique using two similar instruments and the results compared with the theory. It is demonstrated that the parameterization of experimental data can be used to formulate a simple calculation algorithm for real-time SIFT-MS measurements of D abundance to an accuracy of 1% below 1000 ppm and degrades to about 2% at 10,000 ppm.

References
1.
John B, Tan B, Dainty S, Spanel P, Smith D, Davies S . Plasma volume, albumin, and fluid status in peritoneal dialysis patients. Clin J Am Soc Nephrol. 2010; 5(8):1463-70. PMC: 2924416. DOI: 10.2215/CJN.09411209. View

2.
Davies S, Spanel P, Smith D . Rapid measurement of deuterium content of breath following oral ingestion to determine body water. Physiol Meas. 2002; 22(4):651-9. DOI: 10.1088/0967-3334/22/4/301. View

3.
Chan C, Smith D, Spanel P, McIntyre C, Davies S . A non-invasive, on-line deuterium dilution technique for the measurement of total body water in haemodialysis patients. Nephrol Dial Transplant. 2008; 23(6):2064-70. PMC: 5207314. DOI: 10.1093/ndt/gfn045. View

4.
Asghar R, Diskin A, Spanel P, Smith D, Davies S . Influence of convection on the diffusive transport and sieving of water and small solutes across the peritoneal membrane. J Am Soc Nephrol. 2004; 16(2):437-43. DOI: 10.1681/ASN.2004060506. View

5.
Chan C, McIntyre C, Smith D, Spanel P, Davies S . Combining near-subject absolute and relative measures of longitudinal hydration in hemodialysis. Clin J Am Soc Nephrol. 2009; 4(11):1791-8. PMC: 2774951. DOI: 10.2215/CJN.02510409. View