» Articles » PMID: 11014448

Selected Ion Flow Tube Mass Spectrometry Analyses of Stable Isotopes in Water: Isotopic Composition of H3O+ and H3O+ (H2O)3 Ions in Exchange Reactions with Water Vapor

Overview
Specialty Chemistry
Date 2000 Oct 3
PMID 11014448
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A new method has been developed for the determination of the isotope abundance ratios of deuterium, D, and oxygen-18, 18O, in water vapor (and water) using selected ion flow tube mass spectrometry (SIFT-MS). H3O+ ions are injected into the helium carrier gas where they associate with the H2O and HDO molecules in a sample of water introduced into the carrier gas. The D and 18O contents of the product cluster ions H8DO4+ and H9(18)OO3+ at m/e = 74 and 75, respectively, are determined by reference to the majority cluster ion H9O4+ at m/e = 73. Allowance is made for the contribution of the H8(17)OO3+ ions to the m/z = 74 ions. Absolute isotopic ratios are measured within seconds without the need for precalibration of the SIFT-MS instrument, currently to an accuracy of better than 2%.

Citing Articles

Exhaled air profile in the early diagnosis of ventilator-associated pneumonia.

Figueiredo R, Silva J, Bianchini I, Rocha L, Goncalves R, Ritter C Crit Care Sci. 2024; 36:e20240194en.

PMID: 39417432 PMC: 11463982. DOI: 10.62675/2965-2774.20240194-en.


Smelling the Disease: Diagnostic Potential of Breath Analysis.

Sharma A, Kumar R, Varadwaj P Mol Diagn Ther. 2023; 27(3):321-347.

PMID: 36729362 PMC: 9893210. DOI: 10.1007/s40291-023-00640-7.


Monitoring type 2 diabetes from volatile faecal metabolome in Cushing's syndrome and single Afmid mouse models via a longitudinal study.

Lourenco C, Kelly D, Cantillon J, Cauchi M, Yon M, Bentley L Sci Rep. 2019; 9(1):18779.

PMID: 31827172 PMC: 6906526. DOI: 10.1038/s41598-019-55339-9.


Determination of the deuterium abundances in water from 156 to 10,000 ppm by SIFT-MS.

Spanel P, Shestivska V, Chippendale T, Smith D J Am Soc Mass Spectrom. 2011; 22(1):179-86.

PMID: 21472556 DOI: 10.1007/s13361-010-0019-2.


Measuring transport of water across the peritoneal membrane.

Asghar R, Diskin A, Spanel P, Smith D, Davies S Kidney Int. 2003; 64(5):1911-5.

PMID: 14531827 PMC: 5207308. DOI: 10.1046/j.1523-1755.2003.00253.x.


References
1.
Smith D, Spanel P . The novel selected-ion flow tube approach to trace gas analysis of air and breath. Rapid Commun Mass Spectrom. 1996; 10(10):1183-98. DOI: 10.1002/(SICI)1097-0231(19960731)10:10<1183::AID-RCM641>3.0.CO;2-3. View