In Vivo 31P Spectroscopy by Fully Adiabatic Extended Image Selected in Vivo Spectroscopy: a Comparison Between 3 T and 7 T
Overview
Affiliations
An improved image selected in vivo spectroscopy (ISIS) sequence for localized (31)P magnetic resonance spectroscopy at 7 T was developed. To reduce errors in localization accuracy, adiabatic excitation, gradient offset independent adiabatic inversion pulses, and a special extended ISIS ordering scheme were used. The localization accuracy of extended ISIS was investigated in phantoms. The possible spectral quality and reproducibility in vivo was explored in a volunteer (brain, muscle, and liver). A comparison between 3 T and 7 T was performed in five volunteers. Adiabatic extended ISIS provided high spectral quality and accurate localization. The contamination in phantom experiments was only ∼5%, even if a pulse repetition time ∼ 1.2·T(1) was chosen to maximize the signal-to-noise ratio per unit time. High reproducibility was found in the calf muscle for 2.5 cm isotropic voxels at 7 T. When compared with 3 T, localized (31)P magnetic resonance spectroscopy in the human calf muscle at 7 T provided ∼3.2 times higher signal-to-noise ratio (as judged from phosphocreatine peak amplitude in frequency domain after matched filtering). At 7 T, extended ISIS allowed the performance of high-quality localized (31)P magnetic resonance spectroscopy in a short measurement time (∼3 to 4 min) and isotropic voxel sizes of ∼2.5 to 3 cm. With such short measurement times, localized (31)P magnetic resonance spectroscopy has the potential to be applied not only for clinical research but also for routine clinical practice.
Jett S, Dyke J, Andy C, Schelbaum E, Jang G, Yepez C Sci Rep. 2022; 12(1):22087.
PMID: 36543814 PMC: 9772209. DOI: 10.1038/s41598-022-26573-5.
Phosphorus MRS of healthy human spleen.
Weis J, Jafar M, Liss P NMR Biomed. 2022; 35(10):e4779.
PMID: 35642280 PMC: 9540626. DOI: 10.1002/nbm.4779.
Dziadosz M, Hoefemann M, Doring A, Marjanska M, Auerbach E, Kreis R Magn Reson Med. 2022; 88(3):1027-1038.
PMID: 35526238 PMC: 9322547. DOI: 10.1002/mrm.29267.
Ultra-High-Field MRI in the Diagnosis and Management of Gliomas: A Systematic Review.
Shaffer A, Kwok S, Naik A, Anderson A, Lam F, Wszalek T Front Neurol. 2022; 13:857825.
PMID: 35449515 PMC: 9016277. DOI: 10.3389/fneur.2022.857825.
Pfleger L, Gajdosik M, Wolf P, Smajis S, Fellinger P, Kuehne A J Magn Reson Imaging. 2018; 49(2):597-607.
PMID: 30291654 PMC: 6586048. DOI: 10.1002/jmri.26225.