Development of Departmental Standard for Traceability of Measured Activity for I-131 Therapy Capsules Used in Nuclear Medicine

Overview
Journal J Med Phys
Date 2011 Mar 25
PMID 21430859
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

International Basic Safety Standards (International Atomic Energy Agency, IAEA) provide guidance levels for diagnostic procedures in nuclear medicine indicating the maximum usual activity for various diagnostic tests in terms of activities of injected radioactive formulations. An accuracy of ± 10% in the activities of administered radio-pharmaceuticals is being recommended, for expected outcome in diagnostic and therapeutic nuclear medicine procedures. It is recommended that the long-term stability of isotope calibrators used in nuclear medicine is to be checked periodically for their performance using a long-lived check source, such as Cs-137, of suitable activity. In view of the un-availability of such a radioactive source, we tried to develop methods to maintain traceability of these instruments, for certifying measured activities for human use. Two re-entrant chambers [(HDR 1000 and Selectron Source Dosimetry System (SSDS)] with I-125 and Ir-192 calibration factors in the Department of Radiotherapy were used to measure Iodine-131 (I-131) therapy capsules to establish traceability to Mark V isotope calibrator of the Department of Nuclear Medicine. Special nylon jigs were fabricated to keep I-131 capsule holder in position. Measured activities in all the chambers showed good agreement. The accuracy of SSDS chamber in measuring Ir-192 activities in the last 5 years was within 0.5%, validating its role as departmental standard for measuring activity. The above method is adopted because mean energies of I-131 and Ir-192 are comparable.

Citing Articles

Radioactive iodine (I-131) therapy isolation rooms: Introduction of lead glass window on the wall for patient comfort and better ambience.

Al Aamri M, Ravichandran R, Balushi N World J Nucl Med. 2019; 18(1):42-44.

PMID: 30774545 PMC: 6357721. DOI: 10.4103/wjnm.WJNM_18_18.


Therapeutic applications of radioactive (131)iodine: Procedures and incidents with capsules.

Al Aamri M, Ravichandran R, Binukumar J, Balushi N Indian J Nucl Med. 2016; 31(3):176-8.

PMID: 27385885 PMC: 4918478. DOI: 10.4103/0972-3919.183603.

References
1.
Hare D, Hendee W, Whitney W, Chaney E . Accuracy of well ionization chamber isotope calibrators. J Nucl Med. 1974; 15(12):1138-41. View

2.
Goetsch S, Attix F, Pearson D, Thomadsen B . Calibration of 192Ir high-dose-rate afterloading systems. Med Phys. 1991; 18(3):462-7. DOI: 10.1118/1.596649. View

3.
Meier D, Brill D, Becker D, Clarke S, Silberstein E, Royal H . Procedure guideline for therapy of thyroid disease with (131)iodine. J Nucl Med. 2002; 43(6):856-61. View

4.
Baltas D, Geramani K, Ioannidis G, Hierholz K, Rogge B, Kolotas C . Comparison of calibration procedures for 192Ir high-dose-rate brachytherapy sources. Int J Radiat Oncol Biol Phys. 1999; 43(3):653-61. DOI: 10.1016/s0360-3016(98)00423-4. View

5.
Vandana S, Sharma S . Long term response stability of a well-type ionization chamber used in calibration of high dose rate brachytherapy sources. J Med Phys. 2010; 35(2):100-3. PMC: 2884301. DOI: 10.4103/0971-6203.62200. View