Arterial Pressure Allows Monitoring the Changes in Cardiac Output Induced by Volume Expansion but Not by Norepinephrine
Overview
Emergency Medicine
Authors
Affiliations
Objective: To evaluate to which extent the systemic arterial pulse pressure could be used as a surrogate of cardiac output for assessing the effects of a fluid challenge and of norepinephrine.
Design: Observational study.
Setting: Medical intensive care unit.
Patients: Patients with an acute circulatory failure who received a fluid challenge (228 patients, group 1) or in whom norepinephrine was introduced or increased (145 patients, group 2).
Interventions: We measured the systolic, diastolic, and mean arterial pressure, pulse pressure, and the transpulmonary thermodilution cardiac output before and after the therapeutic interventions.
Main Results: In group 1, the fluid challenge significantly increased cardiac output by 24% ± 25%. It significantly increased cardiac output by ≥15% (+35% ± 27%) in 142 patients ("responders"). The fluid-induced changes in cardiac output were correlated with the changes in pulse pressure (r = .56, p < .0001), systolic arterial pressure (r = .55, p < .0001), diastolic arterial pressure (r = .37, p < .0001), and mean arterial pressure (r = .52, p < .0001). At multivariate analysis, changes in pulse pressure were significantly related to changes in stroke volume (multiple r = .52) and to age (r = .12). A fluid-induced increase in pulse pressure of ≥17% allowed detecting a fluid-induced increase in cardiac output of ≥15% with a sensitivity of 65[56-72]% and a specificity of 85[76-92]%. The area under the receiver operating characteristic curves for the fluid-induced changes in mean arterial pressure and in diastolic arterial pressure was significantly lower than for pulse pressure. In group 2, the introduction/increase of norepinephrine significantly increased cardiac output by 14% ± 18%. The changes in cardiac output induced by the introduction/increase in the dose of norepinephrine were correlated with the changes in pulse pressure and systolic arterial pressure (r = .21 and .29, respectively, p = .001) but to a significantly lesser extent than in group 1.
Conclusions: Pulse pressure and systolic arterial pressure could be used for detecting the fluid-induced changes in cardiac output, in spite of a significant proportion of false-negative cases. By contrast, the changes in pulse pressure and systolic arterial pressure were unable to detect the changes in cardiac output induced by norepinephrine.
Why do we use transpulmonary thermodilution and pulmonary artery catheter in severe shock patients?.
Monnet X, Lai C, De Backer D Ann Intensive Care. 2025; 15(1):7.
PMID: 39808220 PMC: 11732821. DOI: 10.1186/s13613-024-01400-4.
Passive leg raising test versus rapid fluid challenge in critically ill medical patients.
Majunke N, Philipp D, Weidhase L, Pasieka B, Kunz K, Seidel F Med Klin Intensivmed Notfmed. 2024; .
PMID: 39240330 DOI: 10.1007/s00063-024-01176-2.
Juneja D, Nasa P, Chanchalani G, Cherian A, Jagiasi B, Javeri Y Indian J Crit Care Med. 2024; 28(Suppl 2):S4-S19.
PMID: 39234230 PMC: 11369916. DOI: 10.5005/jp-journals-10071-24682.
De Backer D, Hajjar L, Monnet X Intensive Care Med. 2024; 50(11):1912-1915.
PMID: 39102028 DOI: 10.1007/s00134-024-07566-6.
Ozkarakas H, Ucar O, Tekgul Z, Ozmuk O, Ozturk M, Bilgin M Ulus Travma Acil Cerrahi Derg. 2024; 30(2):90-96.
PMID: 38305657 PMC: 10977503. DOI: 10.14744/tjtes.2024.37309.