Carbon Tube Electrodes for Electrocardiography-gated Cardiac Multimodality Imaging in Mice

Overview
Date 2011 Feb 22
PMID 21333165
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

This report describes a simple design of noninvasive carbon tube electrodes that facilitates electrocardiography (ECG) in mice during cardiac multimodality preclinical imaging. Both forepaws and the left hindpaw, covered by conductive gel, of mice were placed into the openings of small carbon tubes. Cardiac ECG-gated single-photon emission CT, X-ray CT, and MRI were tested (n = 60) in 20 mice. For all applications, electrodes were used in a warmed multimodality imaging cell. A heart rate of 563 ± 48 bpm was recorded from anesthetized mice regardless of the imaging technique used, with acquisition times ranging from 1 to 2 h.

Citing Articles

A System-Agnostic, Adaptable and Extensible Animal Support Cradle System for Cardio-Respiratory-Synchronised, and Other, Multi-Modal Imaging of Small Animals.

Kersemans V, Gilchrist S, Allen P, Wallington S, Kinchesh P, Prentice J Tomography. 2021; 7(1):39-54.

PMID: 33681462 PMC: 7934707. DOI: 10.3390/tomography7010004.


Systematic Review: Anaesthetic Protocols and Management as Confounders in Rodent Blood Oxygen Level Dependent Functional Magnetic Resonance Imaging (BOLD fMRI)-Part A: Effects of Changes in Physiological Parameters.

Steiner A, Rousseau-Blass F, Schroeter A, Hartnack S, Bettschart-Wolfensberger R Front Neurosci. 2020; 14:577119.

PMID: 33192261 PMC: 7646331. DOI: 10.3389/fnins.2020.577119.

References
1.
Vallee J, Ivancevic M, Nguyen D, Morel D, Jaconi M . Current status of cardiac MRI in small animals. MAGMA. 2004; 17(3-6):149-56. DOI: 10.1007/s10334-004-0066-4. View

2.
Berr S, Roy R, French B, Yang Z, Gilson W, Kramer C . Black blood gradient echo cine magnetic resonance imaging of the mouse heart. Magn Reson Med. 2005; 53(5):1074-9. DOI: 10.1002/mrm.20487. View

3.
Choquet P, Breton E, Goetz C, Marin C, Constantinesco A . Dedicated low-field MRI in mice. Phys Med Biol. 2009; 54(17):5287-99. DOI: 10.1088/0031-9155/54/17/014. View

4.
Van Genderingen H, Sprenger M, de Ridder J, van Rossum A . Carbon-fiber electrodes and leads for electrocardiography during MR imaging. Radiology. 1989; 171(3):872. DOI: 10.1148/radiology.171.3.2717770. View

5.
Badea C, Fubara B, Hedlund L, Johnson G . 4-D micro-CT of the mouse heart. Mol Imaging. 2005; 4(2):110-6. DOI: 10.1162/15353500200504187. View