Purpose: To evaluate the effect of CT perfusion (CTp) protocol modifications on quantitative perfusion parameters, radiation dose and data processing time.

Materials & Methods: CTp datasets of 30 patients (21M:9F) with rectal (n = 24) or retroperitoneal (n = 6) tumours were studied. Standard CTp protocol included 50 sec cine-phase (0.5 sec/rotation) and delayed-phase after 70 ml contrast bolus at 5-7 ml/sec. CTp-data was sub-sampled to generate modified datasets (n = 105) with cine-phase(n = 15) alone, varying cine-phase duration (20-40 sec, n = 45) and varying temporal sampling-interval (1-3 sec, n = 45). The estimated CTp parameters (BF,BV,MTT&PS) and radiation dose of standard CTp served as reference for comparison.

Results: CTp with 50 sec cine-phase showed moderate to high correlation with standard CTp for BF&MTT (r = 0.96&0.85) and low correlation for BV (0.75, p = 0.04). Limiting cine-phase duration to 30 sec demonstrated comparable results for BF&MTT, while considerable variation in CTp values existed at 20 sec. There was moderate-to-high correlation of CTp parameters with sampling interval of 1&2 sec (r = 0.83-0.97, p > 0.05), while at 3 sec only BF showed high correlation (r = 0.96, p = 0.05). Increasing sampling interval (47-60%) and reducing cine-phase duration substantially reduced dose(30.8-65%) which paralleled reduced data processing time (3-10 min).

Conclusion: Limiting CTp cine-phase to 30 sec results in comparable BF&MTT values and increasing cine-phase sampling interval to 2 sec provides good correlation for all CTp parameters with substantial dose reduction and improved computational efficiency.

Citing Articles

Quantitative evaluation of pancreatic neuroendocrine tumors utilizing dual-source CT perfusion imaging.

Liu G, Gao Y, Li X, Huan Y, Chen J, Deng Y BMC Med Imaging. 2024; 24(1):325.

PMID: 39623298 PMC: 11613872. DOI: 10.1186/s12880-024-01511-1.


Effect of scan duration on CT perfusion values in metastases from renal cell carcinoma.

Ng C, Chandler A, Chen Y, Wei W, Tannir N, Hobbs B Res Diagn Interv Imaging. 2024; 6:100028.

PMID: 39077545 PMC: 11265368. DOI: 10.1016/j.redii.2023.100028.


Intra- and interobserver reproducibility of pancreatic perfusion by computed tomography.

Garcia T, Engelholm J, Vouche M, Hirakata V, Leitao C Sci Rep. 2019; 9(1):6043.

PMID: 30988325 PMC: 6465241. DOI: 10.1038/s41598-019-42519-w.


Variability and Reproducibility of 3-generation dual-source dynamic volume perfusion CT Parameters in Comparison to MR-perfusion Parameters in Rectal Cancer.

Sudarski S, Henzler T, Floss T, Gaa T, Meyer M, Haubenreisser H Sci Rep. 2018; 8(1):6868.

PMID: 29720622 PMC: 5932032. DOI: 10.1038/s41598-018-25307-w.


Reproducibility and variability of very low dose hepatic perfusion CT in metastatic liver disease.

Topcuoglu O, Karcaaltincaba M, Akata D, Ozmen M Diagn Interv Radiol. 2016; 22(6):495-500.

PMID: 27759566 PMC: 5098942. DOI: 10.5152/dir.2016.16612.


References
1.
Miles K . Perfusion imaging with computed tomography: brain and beyond. Eur Radiol. 2008; 16 Suppl 7:M37-43. DOI: 10.1007/s10406-006-0194-1. View

2.
Sahani D, Holalkere N, Mueller P, Zhu A . Advanced hepatocellular carcinoma: CT perfusion of liver and tumor tissue--initial experience. Radiology. 2007; 243(3):736-43. DOI: 10.1148/radiol.2433052020. View

3.
DAssignies G, Couvelard A, Bahrami S, Vullierme M, Hammel P, Hentic O . Pancreatic endocrine tumors: tumor blood flow assessed with perfusion CT reflects angiogenesis and correlates with prognostic factors. Radiology. 2008; 250(2):407-16. DOI: 10.1148/radiol.2501080291. View

4.
Kamena A, Streitparth F, Grieser C, Lehmkuhl L, Jamil B, Wojtal K . Dynamic perfusion CT: optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients. Eur J Radiol. 2007; 64(1):111-8. DOI: 10.1016/j.ejrad.2007.02.025. View

5.
Goh V, Padhani A . Imaging tumor angiogenesis: functional assessment using MDCT or MRI?. Abdom Imaging. 2005; 31(2):194-9. DOI: 10.1007/s00261-005-0387-4. View