» Articles » PMID: 2121843

Elimination of Variable Vasomotor Tone in Studies with Repeated Quantitative Coronary Angiography

Overview
Date 1990 Jan 1
PMID 2121843
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

In quantitative coronary angiographic studies, unintentional changes of coronary vasomotor tone may have a significant influence on the coronary artery diameters, thereby increasing the variability in the measurements. To obtain objective data on these measurement variabilities, two protocols were designed to assess the influences of ionic and nonionic radiographic contrast media on the mean diameters of angiographically normal coronary arteries. The vessel sizes were determined with the CAAS using automated edge detection techniques. In 21 patients (study no. I), coronary angiograms were taken in identical angiographic projections before (control), and immediately following several (at average 7) subsequent diagnostic dye injections administered over a period of about 7 min. The ionic contrast agent diatrizoate 76% induced a coronary dilation of 19 +/- 7% (mean +/- s.d., p less than 0.001; n = 10); the nonionic agent iopromide 370 increased the coronary artery diameters by only 6 +/- 4% (p less than 0.01; n = 11). In another 11 patients (study no. II) coronary angiograms were obtained using the nonionic contrast medium iopamidol 300 at 5, 8, 10 and 11 min after the control acquisition; this protocol was repeated in the same patients with diatrizoate 76%. With iopamidol, coronary diameter changes were not significant at any time; with diatrizoate, however, coronary dilation was measured at 10 min (2 +/- 2%; p less than 0.01) and at 11 min (10 +/- 3%; p less than 0.001). In a third study it was tested, whether standardization of coronary vasomotor tone (e.g. in coronary angiographic follow-up studies) is possible by the induction of a reproducible maximum coronary dilation with nitrocompounds. In 12 patients, the mean diameters of angiographically normal coronary segments were analyzed before and at various times after i.v. administration (over 4 min) of 0.025 mg SIN-1/kg bodyweight. Coronary dilation was maximal at 10 or 15 min after the onset of the SIN-1-infusion (29 +/- 5%; p less than 0.001). 0.8 mg nitroglycerin given s.l. at 15 min did not further dilate the coronary arteries (28 +/- 7%). One hour after SIN-1, coronary dilation still amounted to an average of 24 +/- 8% (p less than 0.001) and became 'maximal' again, when 0.8 mg nitroglycerin was again administered sublingually (28 +/- 8%; p less than 0.001). In conclusion, short-term variability of coronary vasomotor tone induced by ionic radiographic contrast media can be eliminated by the use of nonionic contrast agents and observation of injection intervals of at least 2 min. In quantitative coronary angiographic follow-up studies, as well as during acute interventions (e.g., PTCA), identical baseline vasomotor tone can be achieved by induction of the maximal coronary dilation using nitrocompounds.

Citing Articles

A clinical strategy to improve the diagnostic performance of 3T non-contrast coronary MRA and noninvasively evaluate coronary distensibility: combination of diastole and systole imaging.

Lu H, Zhao S, Tian D, Chen Y, Ma J, Ge M J Cardiovasc Magn Reson. 2023; 25(1):67.

PMID: 37993897 PMC: 10666457. DOI: 10.1186/s12968-023-00982-5.


Noninvasive test of nitrate-induced coronary vasomotion by 1.5-T whole-heart 3D magnetic resonance angiography using a T2-prepared SSFP sequence.

Jin H, Zeng M, Yun H, Ge M, Ma J, Yang S Int J Cardiovasc Imaging. 2011; 28(7):1707-16.

PMID: 22187200 DOI: 10.1007/s10554-011-9999-7.


How to standardize vasomotor tone in serial studies based on quantitation of coronary dimensions?.

Jost S, Nolte C, Sturm M, Hausleiter J, Hausmann D Int J Card Imaging. 1999; 14(6):357-72.

PMID: 10453390 DOI: 10.1023/a:1006076409185.


Quantitative angiographic follow-up studies on the development of coronary artery disease: which coronary segments should be analyzed? Experience from INTACT.

Jost S, Deckers J, Rafflenbeul W, Reiber J, Nikutta P, Wiese B Int J Card Imaging. 1993; 9(1):29-37.

PMID: 8491998 DOI: 10.1007/BF01142930.


Features of the angiographic evaluation of the INTACT study. International Nifedipine Trial on Antiatherosclerotic Therapy.

Jost S, Deckers J, Rafflenbeul W, Hecker H, Nellessen U, Wiese B Cardiovasc Drugs Ther. 1990; 4 Suppl 5:1037-45.

PMID: 2076391 DOI: 10.1007/BF02018314.

References
1.
Serruys P, Umans V, Heyndrickx G, van den Brand M, de Feyter P, Wijns W . Elective PTCA of totally occluded coronary arteries not associated with acute myocardial infarction; short-term and long-term results. Eur Heart J. 1985; 6(1):2-12. DOI: 10.1093/oxfordjournals.eurheartj.a061750. View

2.
Jost S, Rafflenbeul W, Gerhardt U, Nellessen U, Reil G, Hecker H . [Comparison of high and low osmolar roentgen contrast media in quantitative coronary angiography]. Z Kardiol. 1988; 77(12):755-66. View

3.
Jost S, Rafflenbeul W, Mogwitz B, Nellessen U, Bossaller C, Zwicky P . Coronary vasodilation with dihydropyridines--a pharmacokinetic study. Eur Heart J. 1989; 10 Suppl F:147-52. DOI: 10.1093/eurheartj/10.suppl_f.147. View

4.
Rafflenbeul W, Urthaler F, RUSSELL R, Lichtlen P, James T . Dilation of coronary artery stenoses after isosorbide dinitrate in man. Br Heart J. 1980; 43(5):546-9. PMC: 482339. DOI: 10.1136/hrt.43.5.546. View

5.
Gage J, Hess O, Murakami T, Ritter M, Grimm J, KRAYENBUEHL H . Vasoconstriction of stenotic coronary arteries during dynamic exercise in patients with classic angina pectoris: reversibility by nitroglycerin. Circulation. 1986; 73(5):865-76. DOI: 10.1161/01.cir.73.5.865. View