320-row CT Coronary Angiography: Effect of 100-kV Tube Voltages on Image Quality, Contrast Volume, and Radiation Dose

Overview
Publisher Springer
Specialty Radiology
Date 2010 Nov 27
PMID 21110100
Citations 23
Authors
Affiliations
Soon will be listed here.
Abstract

To prospectively evaluate image quality parameters, contrast volume and radiation dose at the 100-kilovolt (kV) setting during coronary computed tomographic angiography (CCTA) on a 320-row computed tomography scanner. We enrolled 107 consecutive patients with a heart rate <65 beats per minute (bpm) undergoing prospective electrocardiogram (ECG)-triggered CCTA. Forty patients with a body mass index (BMI) <25 kg/m(2) were scanned using 100-kV tube voltage settings, while 67 patients were scanned using 120-kV protocols. Image quality was assessed by two readers unaware of patient information and scan parameters. Attenuation in the aorta and perivascular fat tissue and image noise were measured. Contrast-to-noise ratios (CNRs) and contrast material volumes were calculated. The effective radiation doses were estimated using a chest conversion coefficient (0.017). Diagnostic image quality was achieved in 98.2% of coronary segments with 100-kV CCTA and 98.6% of coronary segments with 120-kV CCTA, with no significant differences in image quality scores for each coronary segment. Vessel attenuation, image noise, and CNR were not significantly different between the 100- and 120-kV protocols. Mean contrast injection rate and mean material volume were significantly lower for the 100-kV CCTA (4.35 ± 0.28 ml/s and 53.13 ± 3.77 ml, respectively) than for the 120-kV CCTA (5.16 ± 0.21 ml/s and 62.40 ± 3.66 ml respectively; P < 0.001). The effective radiation dose was 2.12 ± 0.19 mSv for 100-kV CCTA, a reduction of 54% compared to 4.61 ± 0.82 mSv for 120-kV CCTA. A 100-kV CCTA can be implemented in patients with a BMI < 25 kg/m(2). The 100-kV setting allows significant reductions in contrast material volume and effective radiation dose while maintaining adequate diagnostic image quality.

Citing Articles

Deep learning reconstruction algorithm and high-concentration contrast medium: feasibility of a double-low protocol in coronary computed tomography angiography.

Caruso D, De Santis D, Tremamunno G, Santangeli C, Polidori T, Bona G Eur Radiol. 2024; .

PMID: 39299952 DOI: 10.1007/s00330-024-11059-x.


The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media.

Huang X, Gao S, Ma Y, Lu X, Jia Z, Hou Y Quant Imaging Med Surg. 2020; 10(3):592-603.

PMID: 32269920 PMC: 7136738. DOI: 10.21037/qims.2020.02.17.


Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography.

Mousavi-Gazafroudi S, Sajjadieh-Khajouei A, Moradi M, Mousavi-Gazafroudi S, Yadegarfar G, Tavakoli M ARYA Atheroscler. 2020; 15(5):205-210.

PMID: 31949446 PMC: 6954360. DOI: 10.22122/arya.v15i5.1406.


Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Tan S, Ng K, Yeong C, Aman R, Sani F, Abdul Aziz Y Quant Imaging Med Surg. 2019; 9(4):552-564.

PMID: 31143647 PMC: 6511728. DOI: 10.21037/qims.2019.03.13.


Diagnostic accuracy of low-radiation coronary computed tomography angiography with low tube voltage and knowledge-based model reconstruction.

Lee J, Kim T, Lee B, Yoon Y, Kwon H, Hong B Sci Rep. 2019; 9(1):1308.

PMID: 30718631 PMC: 6362232. DOI: 10.1038/s41598-018-37870-3.


References
1.
Feuchtner G, Jodocy D, Klauser A, Haberfellner B, Aglan I, Spoeck A . Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study. Eur J Radiol. 2009; 75(1):e51-6. DOI: 10.1016/j.ejrad.2009.07.012. View

2.
de Graaf F, Schuijf J, van Velzen J, Kroft L, de Roos A, Reiber J . Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease. Eur Heart J. 2010; 31(15):1908-15. DOI: 10.1093/eurheartj/ehp571. View

3.
Herzog C, Mulvihill D, Nguyen S, Savino G, Schmidt B, Costello P . Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. AJR Am J Roentgenol. 2008; 190(5):1232-40. DOI: 10.2214/AJR.07.3124. View

4.
Yamamuro M, Tadamura E, Kanao S, Wu Y, Tambara K, Komeda M . Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation. J Comput Assist Tomogr. 2007; 31(2):272-80. DOI: 10.1097/01.rct.0000236422.35761.a1. View

5.
Earls J, Berman E, Urban B, Curry C, Lane J, Jennings R . Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology. 2008; 246(3):742-53. DOI: 10.1148/radiol.2463070989. View