» Articles » PMID: 21081582

64-Slice Multidetector Row CT Angiography of the Abdomen: Comparison of Low Versus High Concentration Iodinated Contrast Media in a Porcine Model

Overview
Journal Br J Radiol
Specialty Radiology
Date 2010 Nov 18
PMID 21081582
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml(-1)) and high-concentration contrast media (HCCM) (370 mg I ml(-1)) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose.

Methods: CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml(-1)), Group B (HCCM; 370 mg I ml(-1)) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg(-1)) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test.

Results: The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose.

Conclusion: 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced.

Citing Articles

Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study.

Li J, Wang Y, Zheng F, Chen X, Lin Y, Zhu C Insights Imaging. 2021; 12(1):166.

PMID: 34767101 PMC: 8589906. DOI: 10.1186/s13244-021-01079-2.


Computed tomography portography of patients with cirrhosis with normal body mass index: Comparison between low-tube-voltage CT with low contrast agent dose and conventional CT.

Liu S, Sheng H, Shi H, Li W, Fan J, He J Medicine (Baltimore). 2018; 97(48):e13141.

PMID: 30508890 PMC: 6283149. DOI: 10.1097/MD.0000000000013141.


Effects of High-concentration contrast material and low-voltage CT on contrast for multiphasic CT of the upper abdomen: comparison using the simulation with virtual monochromatic imaging obtained by fast-switch kVp dual-energy CT.

Sakane M, Kim T, Hori M, Onishi H, Nakamoto A, Tsuboyama T Springerplus. 2014; 3:234.

PMID: 24891998 PMC: 4039664. DOI: 10.1186/2193-1801-3-234.

References
1.
Cademartiri F, de Monye C, Pugliese F, Mollet N, Runza G, van der Lugt A . High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol. 2006; 41(3):349-53. DOI: 10.1097/01.rli.0000191369.76521.09. View

2.
Willmann J, Baumert B, Schertler T, Wildermuth S, Pfammatter T, Verdun F . Aortoiliac and lower extremity arteries assessed with 16-detector row CT angiography: prospective comparison with digital subtraction angiography. Radiology. 2005; 236(3):1083-93. DOI: 10.1148/radiol.2362040895. View

3.
Squillaci E, Fanucci E, Masala S, Nisini A, Tomassini M, Simonetti G . A comparison between two different concentration of contrast media with multidetector CT for the study of abdominal vascular system. Radiol Med. 2003; 104(4):341-50. View

4.
Ichikawa T, Erturk S, Araki T . Multiphasic contrast-enhanced multidetector-row CT of liver: contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients' body-weight-tailored dose of contrast material. Eur J Radiol. 2006; 58(2):165-76. DOI: 10.1016/j.ejrad.2005.11.037. View

5.
Napoli A, Fleischmann D, Chan F, Catalano C, Hellinger J, Passariello R . Computed tomography angiography: state-of-the-art imaging using multidetector-row technology. J Comput Assist Tomogr. 2004; 28 Suppl 1:S32-45. DOI: 10.1097/01.rct.0000120859.80935.10. View