64-slice Multidetector Coronary CT Angiography: in Vitro Evaluation of 68 Different Stents
Overview
Authors
Affiliations
The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% +/-10%) and more realistic lumen attenuation (222 HU +/-66 HU) at the expense of increased noise (15.3 HU +/-3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent diameter.
Meloni A, Maffei E, Positano V, Clemente A, De Gori C, Berti S Cardiovasc Diagn Ther. 2024; 14(4):698-724.
PMID: 39263472 PMC: 11384460. DOI: 10.21037/cdt-24-52.
Meloni A, Maffei E, Clemente A, De Gori C, Occhipinti M, Positano V J Clin Med. 2024; 13(8).
PMID: 38673632 PMC: 11051476. DOI: 10.3390/jcm13082359.
Cardiovascular Applications of Photon-Counting CT Technology: A Revolutionary New Diagnostic Step.
Meloni A, Cademartiri F, Positano V, Celi S, Berti S, Clemente A J Cardiovasc Dev Dis. 2023; 10(9).
PMID: 37754792 PMC: 10531582. DOI: 10.3390/jcdd10090363.
Faria D, Hennessey B, Shabbir A, Mejia-Renteria H, Wang L, Lee J EuroIntervention. 2023; 19(3):203-221.
PMID: 37326378 PMC: 10266405. DOI: 10.4244/EIJ-D-22-00969.
Cademartiri F, Meloni A, Pistoia L, Degiorgi G, Clemente A, De Gori C J Clin Med. 2023; 12(11).
PMID: 37297822 PMC: 10253312. DOI: 10.3390/jcm12113627.