» Articles » PMID: 20933270

The Surface Immobilization of the Neural Adhesion Molecule L1 on Neural Probes and Its Effect on Neuronal Density and Gliosis at the Probe/tissue Interface

Overview
Journal Biomaterials
Date 2010 Oct 12
PMID 20933270
Citations 68
Authors
Affiliations
Soon will be listed here.
Abstract

Brain tissue inflammatory responses, including neuronal loss and gliosis at the neural electrode/tissue interface, limit the recording stability and longevity of neural probes. The neural adhesion molecule L1 specifically promotes neurite outgrowth and neuronal survival. In this study, we covalently immobilized L1 on the surface of silicon-based neural probes and compared the tissue response between L1 modified and non-modified probes implanted in the rat cortex after 1, 4, and 8 weeks. The effect of L1 on neuronal health and survival, and glial cell reactions were evaluated with immunohistochemistry and quantitative image analysis. Similar to previous findings, persistent glial activation and significant decreases of neuronal and axonal densities were found at the vicinity of the non-modified probes. In contrast, the immediate area (100 μm) around the L1 modified probe showed no loss of neuronal bodies and a significantly increased axonal density relative to background. In this same region, immunohistochemistry analyses show a significantly lower activation of microglia and reaction of astrocytes around the L1 modified probes when compared to the control probes. These improvements in tissue reaction induced by the L1 coating are likely to lead to improved functionality of the implanted neural electrodes during chronic recordings.

Citing Articles

Overcoming failure: improving acceptance and success of implanted neural interfaces.

Dalrymple A, Jones S, Fallon J, Shepherd R, Weber D Bioelectron Med. 2025; 11(1):6.

PMID: 40083033 PMC: 11907899. DOI: 10.1186/s42234-025-00168-7.


Advanced age is not a barrier to chronic intracortical single-unit recording in rat cortex.

Nolta N, Christensen M, Tresco P Front Neurosci. 2024; 18:1389556.

PMID: 38817909 PMC: 11138162. DOI: 10.3389/fnins.2024.1389556.


Improving the Biocompatibility and Functionality of Neural Interface Devices with Silica Nanoparticles.

Shi D, Narayanan S, Woeppel K, Cui X Acc Chem Res. 2024; 57(12):1684-1695.

PMID: 38814586 PMC: 11191400. DOI: 10.1021/acs.accounts.4c00160.


Reactive Amine Functionalized Microelectrode Arrays Provide Short-Term Benefit but Long-Term Detriment to Recording Performance.

Sturgill B, Hernandez-Reynoso A, Druschel L, Smith T, Boucher P, Hoeferlin G ACS Appl Bio Mater. 2024; 7(2):1052-1063.

PMID: 38290529 PMC: 10880090. DOI: 10.1021/acsabm.3c01014.


Advances in electrode interface materials and modification technologies for brain-computer interfaces.

Jiao Y, Lei M, Zhu J, Chang R, Qu X Biomater Transl. 2024; 4(4):213-233.

PMID: 38282708 PMC: 10817795. DOI: 10.12336/biomatertransl.2023.04.003.


References
1.
Donoghue J . Connecting cortex to machines: recent advances in brain interfaces. Nat Neurosci. 2002; 5 Suppl:1085-8. DOI: 10.1038/nn947. View

2.
Schwartz A . Cortical neural prosthetics. Annu Rev Neurosci. 2004; 27:487-507. DOI: 10.1146/annurev.neuro.27.070203.144233. View

3.
Bjornsson C, Oh S, Al-Kofahi Y, Lim Y, Smith K, Turner J . Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion. J Neural Eng. 2006; 3(3):196-207. DOI: 10.1088/1741-2560/3/3/002. View

4.
Truccolo W, Friehs G, Donoghue J, Hochberg L . Primary motor cortex tuning to intended movement kinematics in humans with tetraplegia. J Neurosci. 2008; 28(5):1163-78. PMC: 6671402. DOI: 10.1523/JNEUROSCI.4415-07.2008. View

5.
Chen J, Bernreuther C, Dihne M, Schachner M . Cell adhesion molecule l1-transfected embryonic stem cells with enhanced survival support regrowth of corticospinal tract axons in mice after spinal cord injury. J Neurotrauma. 2005; 22(8):896-906. DOI: 10.1089/neu.2005.22.896. View