» Articles » PMID: 20890190

Results of a Survey of Blood Pressure Monitoring by Intensivists in Critically Ill Patients: a Preliminary Study

Overview
Journal Crit Care Med
Date 2010 Oct 5
PMID 20890190
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Maintenance of mean arterial pressure>65 mm Hg has been associated with improved clinical outcomes in many studies of critically ill patients. Current guidelines for the management of septic shock and guidelines for managing other critical illnesses suggest intra-arterial blood pressure measurement is preferred over automated oscillometric noninvasive blood pressure measurement. Despite these recommendations, anecdotal experience suggested that the use of noninvasive blood pressure measurement in our institution and others in preference to intra-arterial blood pressure measurement remained prevalent.

Design: We designed an online survey and sent it by e-mail.

Setting: Intensive care units.

Patients And Subjects: A randomly selected group from the membership of the Society for Critical Care Medicine.

Interventions: None.

Measurements And Main Results: Use of non-invasive and invasive blood pressure devices. Eight hundred eighty individuals received an invitation to complete the survey and 149 responded. We found that 71% (105 of 149) of intensivists estimated the correct cuff size rather than measuring arm circumference directly. In hypotensive patients, 73% of respondents (108 of 149) reported using noninvasive blood pressure measurement measurements for patient management. In patients on a vasopressor medication, 47% (70 of 149) of respondents reported using noninvasive blood pressure measurement for management.

Conclusions: The use of noninvasive blood pressure measurement measurements in critically ill patients is common despite the paucity of evidence validating its accuracy in critically ill patients. Given this widespread use, accuracy and precision validation studies comparing noninvasive blood pressure measurement with intra-arterial blood pressure measurement in critically ill patients should be performed.

Citing Articles

Clinical validation of a wearable ultrasound sensor of blood pressure.

Zhou S, Park G, Longardner K, Lin M, Qi B, Yang X Nat Biomed Eng. 2024; .

PMID: 39567702 DOI: 10.1038/s41551-024-01279-3.


Comparison of Noninvasive Oscillometric and Intra-Arterial Blood Pressure Measurements in Children Admitted to the Pediatric Intensive Care Unit.

Kaur J, Bhargava S, Pooni P, Bhat D, Dhooria G, Arora K J Pediatr Intensive Care. 2024; 13(2):155-161.

PMID: 38919689 PMC: 11196131. DOI: 10.1055/s-0041-1739264.


Defining Intensivists: A Retrospective Analysis of the Published Studies in the United States, 2010-2020.

Halpern N, Tan K, Bothwell L, Boyce L, Dulu A Crit Care Med. 2024; 52(2):223-236.

PMID: 38240506 PMC: 11256975. DOI: 10.1097/CCM.0000000000005984.


Blood pressure monitoring following kidney transplantation in children: a comparison of invasive and noninvasive measurements using Doppler as a benchmark technique.

Kaplan E, Kadmon G, Nahum E, Alfandary H, Haskin O, Weissbach A Pediatr Nephrol. 2022; 38(4):1291-1298.

PMID: 35913567 DOI: 10.1007/s00467-022-05691-2.


Early vesus differed arterial catheterisation in critically ill patients with acute circulatory failure: a multicentre, open-label, pragmatic, randomised, non-inferiority controlled trial: the EVERDAC protocol.

Muller G, Kamel T, Contou D, Ehrmann S, Martin M, Quenot J BMJ Open. 2021; 11(9):e044719.

PMID: 34521655 PMC: 8442046. DOI: 10.1136/bmjopen-2020-044719.