» Articles » PMID: 20730768

Microplate-reader Compatible Perfusion Microbioreactor Array for Modular Tissue Culture and Cytotoxicity Assays

Overview
Journal Biotechnol Prog
Date 2010 Aug 24
PMID 20730768
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

One important application of tissue engineering is to provide novel in vitro models for cell-based assays. Perfusion microbioreactor array provides a useful tool for microscale tissue culture in parallel. However, high-throughput data generation has been a challenge. In this study, a 4 x 4 array of perfusion microbioreactors was developed for plate-reader compatible, time-series quantification of cell proliferation, and cytotoxicity assays. The device was built through multilayer soft lithography. Low-cost nonwoven polyethylene terephthalate fibrous matrices were integrated as modular tissue culture scaffolds. Human colon cancer HT-29 cells with stable expression of enhanced green fluorescent protein were cultured in the device with continuous perfusion and reached a cell density over 5 x 10(7) cells/mL. The microbioreactor array was used to test a chemotherapeutic drug 5-FU for its effect on HT-29 cells in continuous perfusion 3D culture. Compared with conventional 2D cytotoxicity assay, significant drug resistance was observed in the 3D perfusion culture.

Citing Articles

A microfluidic cell chip for virus isolation via rapid screening for permissive cells.

Su W, Qiu J, Mei Y, Zhang X, He Y, Li F Virol Sin. 2022; 37(4):547-557.

PMID: 35504535 PMC: 9437619. DOI: 10.1016/j.virs.2022.04.011.


Multivariate patterning of human pluripotent cells under perfusion reveals critical roles of induced paracrine factors in kidney organoid development.

Glass N, Takasako M, Er P, Titmarsh D, Hidalgo A, Wolvetang E Sci Adv. 2020; 6(2):eaaw2746.

PMID: 31934619 PMC: 6949035. DOI: 10.1126/sciadv.aaw2746.


Microfluidic cell chips for high-throughput drug screening.

Chi C, Ahmed A, Dereli-Korkut Z, Wang S Bioanalysis. 2016; 8(9):921-37.

PMID: 27071838 PMC: 4870726. DOI: 10.4155/bio-2016-0028.


Study of Chemotaxis and Cell-Cell Interactions in Cancer with Microfluidic Devices.

Sai J, Rogers M, Hockemeyer K, Wikswo J, Richmond A Methods Enzymol. 2016; 570:19-45.

PMID: 26921940 PMC: 5378165. DOI: 10.1016/bs.mie.2015.09.023.


Engineering stem cell niches in bioreactors.

Liu M, Liu N, Zang R, Li Y, Yang S World J Stem Cells. 2013; 5(4):124-35.

PMID: 24179601 PMC: 3812517. DOI: 10.4252/wjsc.v5.i4.124.