Objective: To establish a single-cell whole genome amplification (WGA) technique, in combination with comparative genomic hybridization (CGH), for analyzing chromosomal copy number changes, and to explore its clinical application in preimplantation genetic diagnosis (PGD).

Methods: Twelve single-cell samples with known karyotypes, including 5 chorionic villus samples, 4 human embryonic stem cell (hESC) samples and 3 peripheral lymphocyte samples, and 4 single blastomere samples carrying chromosomal abnormalities detected by PGD, were collected for whole genome amplification by combining primer extension preamplification (PEP) with degenerate oligonucleotide primed-PCR (DOP-PCR) amplification. The amplified products labeled by red fluorescence were mixed with control DNA labeled by green fluorescence, and then the mixture was analyzed by CGH. As a comparison, 10 single cell samples were amplified by DOP-PCR only and then CGH analysis was performed.

Results: The amplification using PEP-DOP-PCR was more stable than traditional DOP-PCR. The products of PEP-DOP-PCR range from 100 bp to 1000 bp, with the mean size being about 400 bp. The CGH results were consistent with analyses by other methods. However, only 6 out of 10 single cell samples were successfully amplified by DOP-PCR, and CGH analysis showed a high background and 2 samples showed inconsistent results from other methods.

Conclusion: PEP-DOP-PCR can effectively amplify the whole genome DNA of single cell. Combined with CGH, this WGA method can successfully detect single-cell chromosomal copy number changes, while DOP-PCR was easy to fail to amplify and amplify inhomogeneously, and CGH analysis using this PCR product usually showed high background. These results suggest that PEP-DOP-CGH is a promising method for preimplantation genetic diagnosis.

Citing Articles

Using SNP array to identify aneuploidy and segmental imbalance in translocation carriers.

Xiong B, Tan K, Tan Y, Gong F, Zhang S, Lu C Genom Data. 2015; 2:92-5.

PMID: 26484079 PMC: 4535754. DOI: 10.1016/j.gdata.2014.05.007.


Comparison of whole genome amplification methods for analysis of DNA extracted from microdissected early breast lesions in formalin-fixed paraffin-embedded tissue.

Arneson N, Moreno J, Iakovlev V, Ghazani A, Warren K, McCready D ISRN Oncol. 2012; 2012:710692.

PMID: 22530150 PMC: 3317021. DOI: 10.5402/2012/710692.