» Articles » PMID: 20644628

Determining Vitamin D Status: a Comparison Between Commercially Available Assays

Overview
Journal PLoS One
Date 2010 Jul 21
PMID 20644628
Citations 99
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Vitamin D is not only important for bone health but can also affect the development of several non-bone diseases. The definition of vitamin D insufficiency by serum levels of 25-hydroxyvitamin D depends on the clinical outcome but might also be a consequence of analytical methods used for the definition. Although numerous 25-hydroxyvitamin D assays are available, their comparability is uncertain. We therefore aim to investigate the precision, accuracy and clinical consequences of differences in performance between three common commercially available assays.

Methodology/principal Findings: Serum 25-hydroxyvitamin D levels from 204 twins from the Swedish Twin Registry were determined with high-pressure liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS), a radioimmunoassay (RIA) and a chemiluminescent immunoassay (CLIA). High inter-assay disagreement was found. Mean 25-hydroxyvitamin D levels were highest for the HPLC-APCI-MS technique (85 nmol/L, 95% CI 81-89), intermediate for RIA (70 nmol/L, 95% CI 66-74) and lowest with CLIA (60 nmol/L, 95% CI 56-64). Using a 50-nmol/L cut-off, 8% of the subjects were insufficient using HPLC-APCI-MS, 22% with RIA and 43% by CLIA. Because of the heritable component of 25-hydroxyvitamin D status, the accuracy of each method could indirectly be assessed by comparison of within-twin pair correlations. The strongest correlation was found for HPLC-APCI-MS (r = 0.7), intermediate for RIA (r = 0.5) and lowest for CLIA (r = 0.4). Regression analyses between the methods revealed a non-uniform variance (p<0.0001) depending on level of 25-hydroxyvitamin D.

Conclusions/significance: There are substantial inter-assay differences in performance. The most valid method was HPLC-APCI-MS. Calibration between 25-hydroxyvitamin D assays is intricate.

Citing Articles

Vitamin D content and prevalence of vitamin D deficiency in patients with epilepsy: a systematic review and meta-analysis.

Liu Y, Gong C, Li J, Ning X, Zeng P, Wang L Front Nutr. 2024; 11:1439279.

PMID: 39279896 PMC: 11392846. DOI: 10.3389/fnut.2024.1439279.


Association Between Serum Vitamin D Levels and Retinal Vascular Occlusion: A Systematic Review and Meta-Analysis.

Apivatthakakul A, Jaruvongvanich S, Upala S, Jaruvongvanich V Cureus. 2024; 16(7):e64356.

PMID: 39130960 PMC: 11316675. DOI: 10.7759/cureus.64356.


Association between serum vitamin D level and Graves' disease: a systematic review and meta-analysis.

Pang B, Li L, Liu X, Cao Z, Pang T, Wang Q Nutr J. 2024; 23(1):60.

PMID: 38849834 PMC: 11157715. DOI: 10.1186/s12937-024-00960-2.


Lemon extract supported green synthesis of bimetallic CuO/Ag nanoporous materials for sensitive detection of vitamin D3.

Naikoo G, Almashali F, Habis F, Bano M, Rather J, Hassan I Sci Rep. 2023; 13(1):20482.

PMID: 37993482 PMC: 10665363. DOI: 10.1038/s41598-023-46774-w.


Determination of vitamin D status in singleton and twin gestations using CLIA and LC-MS/MS.

Zgliczynska M, Ostrowska M, Zebrowska K, Szymusik I, Kowalski K, Leszczynska D Endocr Connect. 2023; 12(11).

PMID: 37610766 PMC: 10563645. DOI: 10.1530/EC-23-0201.


References
1.
Snellman G, Melhus H, Gedeborg R, Olofsson S, Wolk A, Pedersen N . Seasonal genetic influence on serum 25-hydroxyvitamin D levels: a twin study. PLoS One. 2009; 4(11):e7747. PMC: 2774516. DOI: 10.1371/journal.pone.0007747. View

2.
Lips P, CHAPUY M, Dawson-Hughes B, Pols H, Holick M . An international comparison of serum 25-hydroxyvitamin D measurements. Osteoporos Int. 1999; 9(5):394-7. DOI: 10.1007/s001980050162. View

3.
Melamed M, Michos E, Post W, Astor B . 25-hydroxyvitamin D levels and the risk of mortality in the general population. Arch Intern Med. 2008; 168(15):1629-37. PMC: 2677029. DOI: 10.1001/archinte.168.15.1629. View

4.
Hogstrom M, Nordstrom A, Nordstrom P . Relationship between vitamin D metabolites and bone mineral density in young males: a cross-sectional and longitudinal study. Calcif Tissue Int. 2006; 79(2):95-101. DOI: 10.1007/s00223-006-0049-8. View

5.
Lips P . Which circulating level of 25-hydroxyvitamin D is appropriate?. J Steroid Biochem Mol Biol. 2004; 89-90(1-5):611-4. DOI: 10.1016/j.jsbmb.2004.03.040. View