» Articles » PMID: 20614994

Real-time Resampling in Fourier Domain Optical Coherence Tomography Using a Graphics Processing Unit

Overview
Journal J Biomed Opt
Date 2010 Jul 10
PMID 20614994
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Fourier domain optical coherence tomography (FD-OCT) requires either a linear-in-wavenumber spectrometer or a computationally heavy software algorithm to recalibrate the acquired optical signal from wavelength to wavenumber. The first method is sensitive to the position of the prism in the spectrometer, while the second method drastically slows down the system speed when it is implemented on a serially oriented central processing unit. We implement the full resampling process on a commercial graphics processing unit (GPU), distributing the necessary calculations to many stream processors that operate in parallel. A comparison between several recalibration methods is made in terms of performance and image quality. The GPU is also used to accelerate the fast Fourier transform (FFT) and to remove the background noise, thereby achieving full GPU-based signal processing without the need for extra resampling hardware. A display rate of 25 framessec is achieved for processed images (1,024 x 1,024 pixels) using a line-scan charge-coupled device (CCD) camera operating at 25.6 kHz.

Citing Articles

Optical Interferometric Fringe Pattern-Incorporated Spectrum Calibration Technique for Enhanced Sensitivity of Spectral Domain Optical Coherence Tomography.

Han S, Wijesinghe R, Jeon D, Han Y, Lee J, Lee J Sensors (Basel). 2020; 20(7).

PMID: 32272646 PMC: 7181120. DOI: 10.3390/s20072067.


Clinical Utility of Intraoperative Tympanomastoidectomy Assessment Using a Surgical Microscope Integrated with an Optical Coherence Tomography.

Lee J, Wijesinghe R, Jeon D, Kim P, Choung Y, Jang J Sci Rep. 2018; 8(1):17432.

PMID: 30479360 PMC: 6258704. DOI: 10.1038/s41598-018-35563-5.


Recovering distance information in spectral domain interferometry.

Bradu A, Israelsen N, Maria M, Marques M, Rivet S, Feuchter T Sci Rep. 2018; 8(1):15445.

PMID: 30337645 PMC: 6194011. DOI: 10.1038/s41598-018-33821-0.


Master slave en-face OCT/SLO.

Bradu A, Kapinchev K, Barnes F, Podoleanu A Biomed Opt Express. 2015; 6(9):3655-69.

PMID: 26417531 PMC: 4574687. DOI: 10.1364/BOE.6.003655.


GPU-accelerated non-uniform fast Fourier transform-based compressive sensing spectral domain optical coherence tomography.

Xu D, Huang Y, Kang J Opt Express. 2014; 22(12):14871-84.

PMID: 24977582 PMC: 4083058. DOI: 10.1364/OE.22.014871.