» Articles » PMID: 20596556

A Self-pumping Lab-on-a-chip for Rapid Detection of Botulinum Toxin

Overview
Journal Lab Chip
Specialties Biotechnology
Chemistry
Date 2010 Jul 3
PMID 20596556
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

A robust poly(dimethylsiloxane) (PDMS) surface treatment was utilized for the development of a self-pumping lab-on-a-chip (LOC) to rapidly detect minute quantities of toxic substances. One such toxin, botulinum neurotoxin (BoNT), is an extremely lethal substance, which has the potential to cause hundreds of thousands of fatalities if as little as a few grams are released into the environment. To prevent such an outcome, a quick (<45 min) and sensitive detection format is needed. We have developed a self-pumping LOC that can sense down to 1 pg of BoNT type A (in a 1 microL sample) within 15 min in an autonomous manner. The key technologies enabling for such a device are a sensitive electrochemical sensor, an optimized fluidic network and a robust hydrophilic PDMS coating, thereby facilitating autonomous delivery of liquid samples for rapid detection. The stability, simplicity and portability of this device make possible for a storable and distributable system for monitoring bioterrorist attacks.

Citing Articles

Wicking pumps for microfluidics.

Aghajanloo B, Losereewanich W, Pastras C, Inglis D Biomicrofluidics. 2024; 18(6):061501.

PMID: 39494378 PMC: 11531334. DOI: 10.1063/5.0218030.


Simultaneous detection of urea and lactate in sweat based on a wearable sweat biosensor.

Yang H, Ji Y, Shen K, Qian Y, Ye C Biomed Opt Express. 2024; 15(1):14-27.

PMID: 38223175 PMC: 10783907. DOI: 10.1364/BOE.505004.


Iron/iron oxide-based magneto-electrochemical sensors/biosensors for ensuring food safety: recent progress and challenges in environmental protection.

Adampourezare M, Hasanzadeh M, Hoseinpourefeizi M, Seidi F RSC Adv. 2023; 13(19):12760-12780.

PMID: 37153517 PMC: 10157298. DOI: 10.1039/d2ra07415j.


A film-lever actuated switch technology for multifunctional, on-demand, and robust manipulation of liquids.

Liang C, Yang Z, Jiang H Nat Commun. 2022; 13(1):4902.

PMID: 35987906 PMC: 9391643. DOI: 10.1038/s41467-022-32676-4.


DNA tetrahedron-mediated immune-sandwich assay for rapid and sensitive detection of PSA through a microfluidic electrochemical detection system.

Feng D, Su J, Xu Y, He G, Wang C, Wang X Microsyst Nanoeng. 2021; 7:33.

PMID: 34567747 PMC: 8433179. DOI: 10.1038/s41378-021-00258-x.