» Articles » PMID: 20478919

Patient-specific Reconstructed Anatomies and Computer Simulations Are Fundamental for Selecting Medical Device Treatment: Application to a New Percutaneous Pulmonary Valve

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation site morphology, size and dynamics, only about 15 per cent of cases are suitable for current devices. In order to increase the number of patients who could benefit from minimally invasive procedures, a new valved stent graft for percutaneous implantation has been designed recently. In this study, patient-specific computational analyses have been applied to investigate the suitability of new device designs, using real data from 62 patients who had undergone surgical pulmonary valve replacement. Magnetic resonance images of these patients before surgery were elaborated using imaging post-processing software to reconstruct the three-dimensional volume of each patient's implantation site. Three stent designs were created and tested in these patient outflow tracts using finite-element simulations: stent graft SG1 resembles the first device tested in animals; stent graft SG2 is a custom device tailored for a specific patient morphology; and stent graft SG3 represents a hypothetical larger device. The three devices showed an implantation success rate of 37 per cent, 42 per cent and 63 per cent, respectively. Using patient-specific simulations, we have shown that a percutaneous approach with these new devices may be possible for many patients who are currently referred for surgery. Furthermore, when the new devices become available, the methodologies described may help clinicians in the decision-making process, by enabling virtual implantation prior to the actual procedure.

Citing Articles

In vitro bench testing using patient-specific 3D models for percutaneous pulmonary valve implantation with Venus P-valve.

Han Y, Shao Z, Sun Z, Han Y, Xu H, Song S Chin Med J (Engl). 2023; 137(8):990-996.

PMID: 37606001 PMC: 11046019. DOI: 10.1097/CM9.0000000000002793.


First hybrid implantations of novel Salus-Valves in patients with severe pulmonary regurgitation: A case series.

Shao Z, Song S, Han Y, Liang W, Fan T Front Cardiovasc Med. 2022; 9:1059664.

PMID: 36505356 PMC: 9729770. DOI: 10.3389/fcvm.2022.1059664.


Modeling risk of coronary obstruction during transcatheter aortic valve replacement.

Heitkemper M, Hatoum H, Azimian A, Yeats B, Dollery J, Whitson B J Thorac Cardiovasc Surg. 2019; 159(3):829-838.e3.

PMID: 31230808 PMC: 6859205. DOI: 10.1016/j.jtcvs.2019.04.091.


Toward predictive modeling of catheter-based pulmonary valve replacement into native right ventricular outflow tracts.

Jolley M, Lasso A, Nam H, Dinh P, Scanlan A, Nguyen A Catheter Cardiovasc Interv. 2018; 93(3):E143-E152.

PMID: 30444053 PMC: 7713792. DOI: 10.1002/ccd.27962.


First human implant of the Alterra Adaptive Prestent : A new self-expanding device designed to remodel the right ventricular outflow tract.

Zahn E, Chang J, Armer D, Garg R Catheter Cardiovasc Interv. 2018; 91(6):1125-1129.

PMID: 29521437 PMC: 5969108. DOI: 10.1002/ccd.27581.


References
1.
Khambadkone S, Coats L, Taylor A, Boudjemline Y, Derrick G, Tsang V . Percutaneous pulmonary valve implantation in humans: results in 59 consecutive patients. Circulation. 2005; 112(8):1189-97. DOI: 10.1161/CIRCULATIONAHA.104.523266. View

2.
Taylor C, Draney M, Ku J, Parker D, Steele B, Wang K . Predictive medicine: computational techniques in therapeutic decision-making. Comput Aided Surg. 1999; 4(5):231-47. DOI: 10.1002/(SICI)1097-0150(1999)4:5<231::AID-IGS1>3.0.CO;2-Z. View

3.
Taylor C, Figueroa C . Patient-specific modeling of cardiovascular mechanics. Annu Rev Biomed Eng. 2009; 11:109-34. PMC: 4581431. DOI: 10.1146/annurev.bioeng.10.061807.160521. View

4.
Lurz P, Puranik R, Nordmeyer J, Muthurangu V, Hansen M, Schievano S . Improvement in left ventricular filling properties after relief of right ventricle to pulmonary artery conduit obstruction: contribution of septal motion and interventricular mechanical delay. Eur Heart J. 2009; 30(18):2266-74. DOI: 10.1093/eurheartj/ehp258. View

5.
Schievano S, Taylor A, Capelli C, Coats L, Walker F, Lurz P . First-in-man implantation of a novel percutaneous valve: a new approach to medical device development. EuroIntervention. 2010; 5(6):745-50. DOI: 10.4244/eijv5i6a122. View