Abstract

Models of lung acinar geometry have been proposed to analytically describe the diffusion of (3)He in the lung (as measured with pulsed gradient spin echo (PGSE) methods) as a possible means of characterizing lung microstructure from measurement of the (3)He ADC. In this work, major limitations in these analytical models are highlighted in simple diffusion weighted experiments with (3)He in cylindrical models of known geometry. The findings are substantiated with numerical simulations based on the same geometry using finite difference representation of the Bloch-Torrey equation. The validity of the existing "cylinder model" is discussed in terms of the physical diffusion regimes experienced and the basic reliance of the cylinder model and other ADC-based approaches on a Gaussian diffusion behaviour is highlighted. The results presented here demonstrate that physical assumptions of the cylinder model are not valid for large diffusion gradient strengths (above approximately 15 mT/m), which are commonly used for (3)He ADC measurements in human lungs.

Citing Articles

Spin Hyperpolarization in Modern Magnetic Resonance.

Eills J, Budker D, Cavagnero S, Chekmenev E, Elliott S, Jannin S Chem Rev. 2023; 123(4):1417-1551.

PMID: 36701528 PMC: 9951229. DOI: 10.1021/acs.chemrev.2c00534.


Application of a stretched-exponential model for morphometric analysis of accelerated diffusion-weighted 129Xe MRI of the rat lung.

Ouriadov A, Fox M, Lindenmaier A, Stirrat E, Serrai H, Santyr G MAGMA. 2020; 34(1):73-84.

PMID: 32632748 DOI: 10.1007/s10334-020-00860-6.


Rapid assessment of pulmonary gas transport with hyperpolarized 129Xe MRI using a 3D radial double golden-means acquisition with variable flip angles.

Ruppert K, Amzajerdian F, Hamedani H, Xin Y, Loza L, Achekzai T Magn Reson Med. 2018; 80(6):2439-2448.

PMID: 29682792 PMC: 6197935. DOI: 10.1002/mrm.27217.


Whole lung morphometry with 3D multiple b-value hyperpolarized gas MRI and compressed sensing.

Chan H, Stewart N, Parra-Robles J, Collier G, Wild J Magn Reson Med. 2016; 77(5):1916-1925.

PMID: 27283321 PMC: 5412864. DOI: 10.1002/mrm.26279.


Noninvasive quantification of alveolar morphometry in elderly never- and ex-smokers.

Paulin G, Ouriadov A, Lessard E, Sheikh K, McCormack D, Parraga G Physiol Rep. 2015; 3(10).