Stenting the Ductus Arteriosus: Case Selection, Technique and Possible Complications

Overview
Date 2010 Mar 20
PMID 20300236
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

Ductal stenting is an attractive alternative to conventional shunt surgery in duct dependent congenital heart disease as it avoids thoracotomy and its related problems. With today's generation of coronary stents which have better profile, flexibility and trackability, ductal stenting may be achieved safely and with considerably less difficulty than previously described.As in Blalock-Taussig (BT) shunt, ductal stenting is indicated mainly in duct-dependent cyanotic lesions chiefly in the neonatal period. Unlike the Patent ductus arteriosus (PDA) as an isolated lesion, the ductus in cyanotic heart disease has a remarkable morphologic variability. The ductus tends to arise more proximally under the aortic arch, giving rise to a vertical ductus or occasionally it may arise from the subclavian artery. It also tends to be long and sometimes very tortuous, rendering stent implantation technically impossible. The ductus in these patients may also insert onto one of the branch pulmonary arteries with some stenosis at the site of insertion. The ductus in Tetralogy of Fallot with pulmonary atresia (TOF-PA) tend to exhibit these morphologic features and to a lesser degree in transposition of great arteries with ventricular septal defect and pulmonary atresia (TGA-VSD-PA) and the more complex forms of univentricular hearts. In the preliminary angiographic evaluation, it is important to delineate these morphologic features as the basis for case selection.Ductal stenting may be done by the retrograde femoral artery route or the antegrade transvenous route depending on the ductus morphology and the underlying cardiac lesion. The detailed techniques and essential hardware are described. Finally, major potential complications of the procedure are described. Acute stent thrombosis is the most serious and potentially catastrophic. Emergent treatment with thrombolytic therapy and mechanical disruption of thrombus are required. With proper case selection, appropriate technique and the right hardware ductal stenting provides reasonable short-medium term palliation in duct-dependent cyanotic heart disease.

Citing Articles

Acute Patent Ductus Arteriosus Stent Occlusion: A Unique Perspective.

Lee J, Mukadam S, Fortuna R, Razzouk A, Nageotte S Pediatr Cardiol. 2024; .

PMID: 39576283 DOI: 10.1007/s00246-024-03713-4.


Impact of Drug Elution on Infectious Outcomes after Ductal Stenting in Newborns.

Zanjani K, Zeinaloo A, Malakan Rad E, Norouzi S, Mirnia K, Gorji M Pediatr Cardiol. 2024; .

PMID: 39231824 DOI: 10.1007/s00246-024-03625-3.


Stenting of the Patent Ductus Arteriosus: A Meta-analysis and Literature Review.

Bauser-Heaton H, Price K, Weber R, El-Said H J Soc Cardiovasc Angiogr Interv. 2024; 1(6):100392.

PMID: 39132356 PMC: 11308046. DOI: 10.1016/j.jscai.2022.100392.


Erratum: Stenting of the Patent Ductus Arteriosus: A Meta-analysis and Literature Review.

Bauser-Heaton H, Price K, Weber R, El-Said H J Soc Cardiovasc Angiogr Interv. 2024; 2(4):101052.

PMID: 39131650 PMC: 11307754. DOI: 10.1016/j.jscai.2023.101052.


Successful Stent Implantation Into the Patent Ductus Arteriosus in Complex Cyanotic Congenital Heart Disease.

Bhugaonkar K, Balwaik K, Masne N Cureus. 2024; 16(3):e56135.

PMID: 38623139 PMC: 11017696. DOI: 10.7759/cureus.56135.


References
1.
Krichenko A, Benson L, Burrows P, MOES C, McLaughlin P, Freedom R . Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol. 1989; 63(12):877-80. DOI: 10.1016/0002-9149(89)90064-7. View

2.
Schneider M, Zartner P, Sidiropoulos A, Konertz W, Hausdorf G . Stent implantation of the arterial duct in newborns with duct-dependent circulation. Eur Heart J. 1998; 19(9):1401-9. DOI: 10.1053/euhj.1998.0977. View

3.
Gewillig M, Boshoff D, Dens J, Mertens L, Benson L . Stenting the neonatal arterial duct in duct-dependent pulmonary circulation: new techniques, better results. J Am Coll Cardiol. 2004; 43(1):107-12. DOI: 10.1016/j.jacc.2003.08.029. View

4.
Abrams S, Walsh K . Arterial duct morphology with reference to angioplasty and stenting. Int J Cardiol. 1993; 40(1):27-33. DOI: 10.1016/0167-5273(93)90227-8. View

5.
Michel-Behnke I, Akintuerk H, Thul J, Bauer J, Hagel K, Schranz D . Stent implantation in the ductus arteriosus for pulmonary blood supply in congenital heart disease. Catheter Cardiovasc Interv. 2004; 61(2):242-52. DOI: 10.1002/ccd.10766. View