Objectives: The goal of this study was to assess a new approach to stent the arterial duct in neonates with a duct-dependent pulmonary circulation.

Background: Previous attempts to stent the neonatal arterial duct were unsatisfactory. Learning from these failures, we speculated that covering the complete length of the duct with current low-profile stents might avoid previous problems.

Methods: Ten neonates with duct-dependent pulmonary circulations through a short straight duct were treated with stent implantation. The duct was crossed with an atraumatic 0.014-inch wire. A low-profile premounted coronary stent (outer diameter <4F, length 13 to 24 mm, diameter 3.0 to 4.0 mm) was positioned within the duct, not protected by a sheath; care was taken to cover the complete length of the duct from the aortaductal junction until well within the pulmonary trunk.

Results: All stents could safely be deployed with adequate pulmonary flow at early- and medium-term follow-up. There were no procedure-related complications; one patient died early from sepsis. All patients had adequate relief of cyanosis for at least three to four months. During follow-up, the pulmonary vasculature bed had grown without distortion. Acute occlusion of a stented duct was not observed. Ductal flow progressively decreased slowly over several months by luminal narrowing, until the stented duct had either become redundant or was dilated/restented or until elective staged surgery was performed.

Conclusions: With current technology, complete stenting of a short straight duct is a safe and effective palliation, allowing adequate growth of the pulmonary arteries.

Citing Articles

Comparison of Immediate Intensive Care Outcomes of Patent Ductus Arteriosus Stenting Versus Modified Blalock-Taussig-Thomas Shunt in Infants With Ductal-Dependent Pulmonary Circulation.

Sirisani J, Haranal M, Soo K, Sivalingam S, Khalid K Pediatr Cardiol. 2024; .

PMID: 39073479 DOI: 10.1007/s00246-024-03591-w.


Personalized Approach in Transcatheter Palliation of Congenital Heart Disease with Duct-Dependent Pulmonary Circulation: Right Ventricular Outflow Tract Stenting vs. Arterial Duct Stenting.

Scalera S, Pizzuto A, Marchese P, Cantinotti M, Franchi E, Marrone C J Pers Med. 2024; 14(3).

PMID: 38541044 PMC: 10971455. DOI: 10.3390/jpm14030302.


Trends in Ductus Arteriosus Stent Versus Blalock-Taussig-Thomas Shunt Use and Comparison of Cost, Length of Stay, and Short-Term Outcomes in Neonates With Ductal-Dependent Pulmonary Blood Flow: An Observational Study Using the Pediatric Health....

Lemley B, Wu L, Roberts A, Shinohara R, Quarshie W, Qureshi A J Am Heart Assoc. 2023; 12(23):e030575.

PMID: 38038172 PMC: 10727347. DOI: 10.1161/JAHA.123.030575.


Advances in pediatric cardiology.

Sperotto F, Guillen J, Milani G, Lava S Eur J Pediatr. 2023; 183(3):983-985.

PMID: 37702768 DOI: 10.1007/s00431-023-05196-6.


Favourable Short- to Mid-Term Outcome after PDA-Stenting in Duct-Dependent Pulmonary Circulation.

Wespi R, Callegari A, Quandt D, Logoteta J, von Rhein M, Kretschmar O Int J Environ Res Public Health. 2022; 19(19).

PMID: 36232092 PMC: 9566406. DOI: 10.3390/ijerph191912794.