» Articles » PMID: 20178370

Fabrication of Two-layered Channel System with Embedded Electrodes to Measure Resistance Across Epithelial and Endothelial Barriers

Overview
Journal Anal Chem
Specialty Chemistry
Date 2010 Feb 25
PMID 20178370
Citations 54
Authors
Affiliations
Soon will be listed here.
Abstract

This manuscript describes a straightforward fabrication process for embedding Ag/AgCl electrodes within a two-layer poly(dimethylsiloxane) (PDMS) microfluidic chip where an upper and a lower channel are separated by a semiporous membrane. This system allows for the reliable real-time measurement of transendothelial and transepithelial electrical resistance (TEER), an accepted quantification of cell monolayer integrity, across cells cultured on membranes inside the microchannels using impedance spectroscopy. The technique eliminates the need for costly or specialized microelectrode fabrication, enabling commercially available wire electrodes to easily be incorporated into PDMS microsystems for measuring TEER under microfluidic environments. The capability of measuring impedance across a confluent cell monolayer is confirmed using (i) brain-derived endothelial cells (bEND.3), (ii) Madin Darby Canine Kidney Cells (MDCK-2), and mouse myoblast (C2C12) (all from ATCC, Manassas, VA). TEER values as a function of cell type and cell culture time were measured and both agree with previously published values from macroscale culture techniques. This system opens new opportunities for conveniently resolving both transendothelial and transepithelial electrical resistance to monitor cell function in real-time in microfluidic cell cultures.

Citing Articles

A microphysiological system for studying barrier health of live tissues in real time.

Way R, Templeton H, Ball D, Cheng M, Tobet S, Chen T Commun Eng. 2024; 3(1):142.

PMID: 39396075 PMC: 11470921. DOI: 10.1038/s44172-024-00285-2.


Revolutionizing Drug Discovery: The Impact of Distinct Designs and Biosensor Integration in Microfluidics-Based Organ-on-a-Chip Technology.

Yuan S, Yuan H, Hay D, Hu H, Wang C Biosensors (Basel). 2024; 14(9).

PMID: 39329800 PMC: 11430660. DOI: 10.3390/bios14090425.


Organs on chips: fundamentals, bioengineering and applications.

Awad N J Artif Organs. 2024; .

PMID: 39134691 DOI: 10.1007/s10047-024-01460-0.


A Microphysiological System for Studying Barrier Health of Live Tissues in Real Time.

Way R, Templeton H, Ball D, Cheng M, Tobet S, Chen T Res Sq. 2024; .

PMID: 38659839 PMC: 11042443. DOI: 10.21203/rs.3.rs-4078220/v1.


Ultra-thin and ultra-porous nanofiber networks as a basement-membrane mimic.

Graybill P, Jacobs 4th E, Jana A, Agashe A, Nain A, Davalos R Lab Chip. 2023; 23(20):4565-4578.

PMID: 37772328 PMC: 10623910. DOI: 10.1039/d3lc00304c.


References
1.
Pantoja R, Nagarah J, Starace D, Melosh N, Blunck R, Bezanilla F . Silicon chip-based patch-clamp electrodes integrated with PDMS microfluidics. Biosens Bioelectron. 2004; 20(3):509-17. DOI: 10.1016/j.bios.2004.02.020. View

2.
Martin R, Gawron A, Lunte S . Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips. Anal Chem. 2000; 72(14):3196-202. DOI: 10.1021/ac000160t. View

3.
Lewis S, Wills N . Electrical properties of the rabbit urinary bladder assessed using gramicidin D. J Membr Biol. 1982; 67(1):45-53. DOI: 10.1007/BF01868646. View

4.
Farinas J, Chow A, Wada H . A microfluidic device for measuring cellular membrane potential. Anal Biochem. 2001; 295(2):138-42. DOI: 10.1006/abio.2001.5202. View

5.
Richardson J, Scalera V, Simmons N . Identification of two strains of MDCK cells which resemble separate nephron tubule segments. Biochim Biophys Acta. 1981; 673(1):26-36. View