» Articles » PMID: 20136098

Graphene and Nanowire Transistors for Cellular Interfaces and Electrical Recording

Overview
Journal Nano Lett
Specialty Biotechnology
Date 2010 Feb 9
PMID 20136098
Citations 66
Authors
Affiliations
Soon will be listed here.
Abstract

Nanowire field-effect transistors (NW-FETs) have been shown to be powerful building blocks for nanoscale bioelectronic interfaces with cells and tissue due to their excellent sensitivity and their capability to form strongly coupled interfaces with cell membranes. Graphene has also been shown to be an attractive building block for nanoscale electronic devices, although little is known about its interfaces with cells and tissue. Here we report the first studies of graphene field effect transistors (Gra-FETs) as well as combined Gra- and NW-FETs interfaced to electrogenic cells. Gra-FET conductance signals recorded from spontaneously beating embryonic chicken cardiomyocytes yield well-defined extracellular signals with signal-to-noise ratio routinely >4. The conductance signal amplitude was tuned by varying the Gra-FET working region through changes in water gate potential, V(wg). Signals recorded from cardiomyocytes for different V(wg) result in constant calibrated extracellular voltage, indicating a robust graphene/cell interface. Significantly, variations in V(wg) across the Dirac point demonstrate the expected signal polarity flip, thus allowing, for the first time, both n- and p-type recording to be achieved from the same Gra-FET simply by offsetting V(wg). In addition, comparisons of peak-to-peak recorded signal widths made as a function of Gra-FET device sizes and versus NW-FETs allowed an assessment of relative resolution in extracellular recording. Specifically, peak-to-peak widths increased with the area of Gra-FET devices, indicating an averaged signal from different points across the outer membrane of the beating cells. One-dimensional silicon NW- FETs incorporated side by side with the two-dimensional Gra-FET devices further highlighted limits in both temporal resolution and multiplexed measurements from the same cell for the different types of devices. The distinct and complementary capabilities of Gra- and NW-FETs could open up unique opportunities in the field of bioelectronics in the future.

Citing Articles

Graphene and its hybrid nanocomposite: A Metamorphoses elevation in the field of tissue engineering.

Singh R, Rawat H, Kumar A, Gandhi Y, Kumar V, Mishra S Heliyon. 2024; 10(13):e33542.

PMID: 39040352 PMC: 11261797. DOI: 10.1016/j.heliyon.2024.e33542.


Multifunctional Nanomaterials for Advancing Neural Interfaces: Recording, Stimulation, and Beyond.

Ranke D, Lee I, Gershanok S, Jo S, Trotto E, Wang Y Acc Chem Res. 2024; 57(13):1803-1814.

PMID: 38859612 PMC: 11223263. DOI: 10.1021/acs.accounts.4c00138.


Graphene-integrated mesh electronics with converged multifunctionality for tracking multimodal excitation-contraction dynamics in cardiac microtissues.

Gao H, Wang Z, Yang F, Wang X, Wang S, Zhang Q Nat Commun. 2024; 15(1):2321.

PMID: 38485708 PMC: 10940632. DOI: 10.1038/s41467-024-46636-7.


Applications of Graphene Field Effect Biosensors for Biological Sensing.

Aran K, Goldsmith B, Moarefian M Adv Biochem Eng Biotechnol. 2024; 187():37-70.

PMID: 38418581 DOI: 10.1007/10_2024_252.


Active Micro-Nano-Collaborative Bioelectronic Device for Advanced Electrophysiological Recording.

Xiang Y, Shi K, Li Y, Xue J, Tong Z, Li H Nanomicro Lett. 2024; 16(1):132.

PMID: 38411852 PMC: 10899154. DOI: 10.1007/s40820-024-01336-1.


References
1.
Mohanty N, Berry V . Graphene-based single-bacterium resolution biodevice and DNA transistor: interfacing graphene derivatives with nanoscale and microscale biocomponents. Nano Lett. 2009; 8(12):4469-76. DOI: 10.1021/nl802412n. View

2.
Ohno Y, Maehashi K, Yamashiro Y, Matsumoto K . Electrolyte-gated graphene field-effect transistors for detecting pH and protein adsorption. Nano Lett. 2009; 9(9):3318-22. DOI: 10.1021/nl901596m. View

3.
Cohen-Karni T, Timko B, Weiss L, Lieber C . Flexible electrical recording from cells using nanowire transistor arrays. Proc Natl Acad Sci U S A. 2009; 106(18):7309-13. PMC: 2678623. DOI: 10.1073/pnas.0902752106. View

4.
Qing Q, Pal S, Tian B, Duan X, Timko B, Cohen-Karni T . Nanowire transistor arrays for mapping neural circuits in acute brain slices. Proc Natl Acad Sci U S A. 2010; 107(5):1882-7. PMC: 2808222. DOI: 10.1073/pnas.0914737107. View

5.
Ingebrandt S, Yeung C, Krause M, Offenhausser A . Cardiomyocyte-transistor-hybrids for sensor application. Biosens Bioelectron. 2001; 16(7-8):565-70. DOI: 10.1016/s0956-5663(01)00170-1. View