Abstract

Objective: The purpose of this study was to compare a 3D T2-weighted imaging sequence with a conventional multiplanar 2D turbo spin-echo T2-weighted sequence in terms of tumor detection and staging of prostate cancer, as well as image quality.

Materials And Methods: Before prostatectomy, 38 men (mean age, 60 years) with prostate cancer underwent MRI of the prostate with multiplanar 2D turbo spin-echo T2-weighted sequences (total acquisition time, approximately 11 minutes 4 seconds) and a 3D T2-weighted sampling perfection with application optimized contrasts sequence with different flip angle evolutions (SPACE) (acquisition time, approximately 3 minutes 52 seconds). Two blinded observers in consensus reviewed 2D turbo spin-echo T2-weighted images and SPACE images for detection of peripheral zone cancer, extracapsular extension, and seminal vesicle invasion. The observers also assessed subjective image quality and measured the signal-to-noise ratio (SNR) of normal peripheral zone and tumor-to-peripheral zone contrast. Prostatectomy was used as the reference standard. The diagnostic accuracy of the two sequences was assessed with generalized estimating equations and McNemar tests. The agreement between sequences was assessed with kappa coefficients. A paired Wilcoxon signed rank test was used to compare the subjective image quality, SNR, and tumor-to-peripheral zone contrast of the two sequences.

Results: For tumor detection and diagnosis of extracapsular extension, there was substantial agreement between the two sequences (kappa = 0.79, kappa = 0.76) with no difference in sensitivity, specificity, positive predictive value, negative predictive value, accuracy (p = 0.25-1), or image quality (p = 0.937). Images obtained with the 2D turbo spin-echo sequence had a significantly higher SNR ratio for normal peripheral zone (p = 0.0010), but SPACE images had significantly greater tumor-to-peripheral zone contrast (p < 0.0001).

Conclusion: In comparison with conventional multiplanar 2D turbo spin-echo MRI of the prostate, 3D T2-weighted SPACE MRI was associated with substantial time saving (nearly 8 minutes), had similar image quality and accuracy in the diagnosis of tumor and extracapsular extension, and had better tumor conspicuity.

Citing Articles

Comparison of model-based versus deep learning-based image reconstruction for thin-slice T2-weighted spin-echo prostate MRI.

Riederer S, Borisch E, Froemming A, Kawashima A, Takahashi N Abdom Radiol (NY). 2024; 49(8):2921-2931.

PMID: 38520510 PMC: 11300170. DOI: 10.1007/s00261-024-04256-1.


Evaluation of Extra-Prostatic Extension on Deep Learning-Reconstructed High-Resolution Thin-Slice T2-Weighted Images in Patients with Prostate Cancer.

Kim M, Kim S, Hong S, Kim Y, Kim H, Kim J Cancers (Basel). 2024; 16(2).

PMID: 38254901 PMC: 10814256. DOI: 10.3390/cancers16020413.


Urethral identification using three-dimensional magnetic resonance imaging and interfraction urethral motion evaluation for prostate stereotactic body radiotherapy.

Kato Y, Okumiya S, Okudaira K, Ito J, Kumagai M, Kamomae T Nagoya J Med Sci. 2023; 85(3):504-517.

PMID: 37829483 PMC: 10565580. DOI: 10.18999/nagjms.85.3.504.


MRI-Based Surrogate Imaging Markers of Aggressiveness in Prostate Cancer: Development of a Machine Learning Model Based on Radiomic Features.

Dominguez I, Rios-Ibacache O, Caprile P, Gonzalez J, San Francisco I, Besa C Diagnostics (Basel). 2023; 13(17).

PMID: 37685317 PMC: 10486695. DOI: 10.3390/diagnostics13172779.


[Prostate Imaging Reporting and Data System (PI-RADS) v 2.1: Overview and Critical Points].

Kim C J Korean Soc Radiol. 2023; 84(1):75-91.

PMID: 36818694 PMC: 9935951. DOI: 10.3348/jksr.2022.0169.