» Articles » PMID: 20086276

Characterization of Volumetric Flow Rate Waveforms at the Carotid Bifurcations of Older Adults

Overview
Journal Physiol Meas
Date 2010 Jan 21
PMID 20086276
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

While it is widely appreciated that volumetric blood flow rate (VFR) dynamics change with age, there has been no detailed characterization of the typical shape of carotid bifurcation VFR waveforms of older adults. Toward this end, retrospectively gated phase contrast magnetic resonance imaging was used to measure time-resolved VFR waveforms proximal and distal to the carotid bifurcations of 94 older adults (age 68 +/- 8 years) with little or no carotid artery disease, recruited from the BLSA cohort of the VALIDATE study of factors in vascular aging. Timings and amplitudes of well-defined feature points from these waveforms were extracted automatically and averaged to produce representative common, internal and external carotid artery (CCA, ICA and ECA) waveform shapes. Relative to young adults, waveforms from older adults were found to exhibit a significantly augmented secondary peak during late systole, resulting in significantly higher resistance index (RI) and flow augmentation index (FAI). Cycle-averaged VFR at the CCA, ICA and ECA were 389 +/- 74, 245 +/- 61 and 125 +/- 49 mL min(-1), respectively, reflecting a significant cycle-averaged outflow deficit of 5%, which peaked at around 10% during systole. A small but significant mean delay of 13 ms between arrivals of ICA versus CCA/ECA peak VFR suggested differential compliance of these vessels. Sex and age differences in waveform shape were also noted. The characteristic waveforms presented here may serve as a convenient baseline for studies of VFR waveform dynamics or as suitable boundary conditions for models of blood flow in the carotid arteries of older adults.

Citing Articles

Development of an in vitro setup for flow studies in a stented carotid artery bifurcation.

Hoving A, Mikhal J, Kuipers H, de Borst G, Slump C Med Biol Eng Comput. 2023; 62(4):1165-1176.

PMID: 38155315 DOI: 10.1007/s11517-023-02977-x.


Understanding intracranial aneurysm sounds via high-fidelity fluid-structure-interaction modelling.

Bruneau D, Steinman D, Valen-Sendstad K Commun Med (Lond). 2023; 3(1):163.

PMID: 37945799 PMC: 10636010. DOI: 10.1038/s43856-023-00396-5.


Cerebral arterial flow dynamics during systole and diastole phases in young and older healthy adults.

Owashi K, Capel C, Baledent O Fluids Barriers CNS. 2023; 20(1):65.

PMID: 37705096 PMC: 10500860. DOI: 10.1186/s12987-023-00467-8.


Onset and nature of flow-induced vibrations in cerebral aneurysms via fluid-structure interaction simulations.

Bruneau D, Valen-Sendstad K, Steinman D Biomech Model Mechanobiol. 2023; 22(3):761-771.

PMID: 36864365 PMC: 10167181. DOI: 10.1007/s10237-022-01679-x.


Evaluation of Plaque Vulnerability via Combination of Hemodynamic Analysis and Simultaneous Non-Contrast Angiography and Intraplaque Hemorrhage (SNAP) Sequence for Carotid Intraplaque Hemorrhage.

Lee U, Kwak H J Pers Med. 2021; 11(9).

PMID: 34575633 PMC: 8465016. DOI: 10.3390/jpm11090856.


References
1.
Himburg H, Dowd S, Friedman M . Frequency-dependent response of the vascular endothelium to pulsatile shear stress. Am J Physiol Heart Circ Physiol. 2007; 293(1):H645-53. DOI: 10.1152/ajpheart.01087.2006. View

2.
Holdsworth D, Norley C, Frayne R, Steinman D, Rutt B . Characterization of common carotid artery blood-flow waveforms in normal human subjects. Physiol Meas. 1999; 20(3):219-40. DOI: 10.1088/0967-3334/20/3/301. View

3.
Zhao S, Xu X, Collins M, Stanton A, Hughes A, Thom S . Flow in carotid bifurcations: effect of the superior thyroid artery. Med Eng Phys. 1999; 21(4):207-14. DOI: 10.1016/s1350-4533(99)00046-6. View

4.
Ford M, Alperin N, Lee S, Holdsworth D, Steinman D . Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol Meas. 2005; 26(4):477-88. DOI: 10.1088/0967-3334/26/4/013. View

5.
Lunt M . Accuracy and limitations of the ultrasonic Doppler blood velocimeter and zero crossing detector. Ultrasound Med Biol. 1975; 2(1):1-10. DOI: 10.1016/0301-5629(75)90035-6. View