Abstract

We developed fully automated software for dynamic susceptibility contrast (DSC) MR perfusion-weighted imaging (PWI) to efficiently and reliably derive critical hemodynamic information for acute stroke treatment decisions. Brain MR PWI was performed in 80 consecutive patients with acute nonlacunar ischemic stroke within 24h after onset of symptom from January 2008 to August 2009. These studies were automatically processed to generate hemodynamic parameters that included cerebral blood flow and cerebral blood volume, and the mean transit time (MTT). To develop reliable software for PWI analysis, we used computationally robust algorithms including the piecewise continuous regression method to determine bolus arrival time (BAT), log-linear curve fitting, arrival time independent deconvolution method and sophisticated motion correction methods. An optimal arterial input function (AIF) search algorithm using a new artery-likelihood metric was also developed. Anatomical locations of the automatically determined AIF were reviewed and validated. The automatically computed BAT values were statistically compared with estimated BAT by a single observer. In addition, gamma-variate curve-fitting errors of AIF and inter-subject variability of AIFs were analyzed. Lastly, two observes independently assessed the quality and area of hypoperfusion mismatched with restricted diffusion area from motion corrected MTT maps and compared that with time-to-peak (TTP) maps using the standard approach. The AIF was identified within an arterial branch and enhanced areas of perfusion deficit were visualized in all evaluated cases. Total processing time was 10.9+/-2.5s (mean+/-s.d.) without motion correction and 267+/-80s (mean+/-s.d.) with motion correction on a standard personal computer. The MTT map produced with our software adequately estimated brain areas with perfusion deficit and was significantly less affected by random noise of the PWI when compared with the TTP map. Results of image quality assessment by two observers revealed that the MTT maps exhibited superior quality over the TTP maps (88% good rating of MTT as compared to 68% of TTP). Our software allowed fully automated deconvolution analysis of DSC PWI using proven efficient algorithms that can be applied to acute stroke treatment decisions. Our streamlined method also offers promise for further development of automated quantitative analysis of the ischemic penumbra.

Citing Articles

Blood-brain barrier breakdown in brain ischemia: Insights from MRI perfusion imaging.

Sasannia S, Leigh R, Bastani P, Shin H, van Zijl P, Knutsson L Neurotherapeutics. 2024; 22(1):e00516.

PMID: 39709246 PMC: 11840350. DOI: 10.1016/j.neurot.2024.e00516.


Multimodal MRI study of the relationship between plaque characteristics and hypoperfusion in patients with transient ischemic attack.

Sui Y, Sun J, Chen Y, Wang W Front Neurol. 2023; 14:1242923.

PMID: 37840913 PMC: 10568067. DOI: 10.3389/fneur.2023.1242923.


Radiomics features of DSC-PWI in time dimension may provide a new chance to identify ischemic stroke.

Guo Y, Yang Y, Cao F, Liu Y, Li W, Yang C Front Neurol. 2022; 13:889090.

PMID: 36408497 PMC: 9672479. DOI: 10.3389/fneur.2022.889090.


Early diagnosis of spinal tuberculosis by magnetic resonance: perfusion weighted imaging in a rabbit model.

Liu X, Wang Y, Jia W BMC Med Imaging. 2022; 22(1):142.

PMID: 35945512 PMC: 9361608. DOI: 10.1186/s12880-022-00870-x.


Neural Network-derived Perfusion Maps for the Assessment of Lesions in Patients with Acute Ischemic Stroke.

Meier R, Lux P, Med B, Jung S, Fischer U, Gralla J Radiol Artif Intell. 2021; 1(5):e190019.

PMID: 33937801 PMC: 8017390. DOI: 10.1148/ryai.2019190019.