» Articles » PMID: 19949799

Quantification of Renal Allograft Perfusion Using Arterial Spin Labeling MRI: Initial Results

Overview
Journal Eur Radiol
Specialty Radiology
Date 2009 Dec 2
PMID 19949799
Citations 42
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To quantify renal allograft perfusion in recipients with stable allograft function and acute decrease in allograft function using nonenhanced flow-sensitive alternating inversion recovery (FAIR)-TrueFISP arterial spin labeling (ASL) MR imaging.

Methods: Following approval of the local ethics committee, 20 renal allograft recipients were included in this study. ASL perfusion measurement and an anatomical T2-weighted single-shot fast spin-echo (HASTE) sequence were performed on a 1.5-T scanner (Magnetom Avanto, Siemens, Erlangen, Germany). T2-weighted MR urography was performed in patients with suspected ureteral obstruction. Patients were assigned to three groups: group a, 6 patients with stable allograft function over the previous 4 months; group b, 7 patients with good allograft function who underwent transplantation during the previous 3 weeks; group c, 7 allograft recipients with an acute deterioration of renal function.

Results: Mean cortical perfusion values were 304.8 +/- 34.4, 296.5 +/- 44.1, and 181.9 +/- 53.4 mg/100 ml/min for groups a, b and c, respectively. Reduction in cortical perfusion in group c was statistically significant.

Conclusion: Our results indicate that ASL is a promising technique for nonenhanced quantification of cortical perfusion of renal allografts. Further studies are required to determine the clinical value of ASL for monitoring renal allograft recipients.

Citing Articles

Contemporary and Emerging MRI Strategies for Assessing Kidney Allograft Complications: Arterial Stenosis and Parenchymal Injury, From the Special Series on Imaging of Fibrosis.

Bane O, Lewis S, Lim R, Carney B, Shah A, Fananapazir G AJR Am J Roentgenol. 2023; 222(3):e2329418.

PMID: 37315018 PMC: 11006565. DOI: 10.2214/AJR.23.29418.


Synthetic Arterial Spin Labeling MRI of the Kidneys for Evaluation of Data Processing Pipeline.

Brumer I, Bauer D, Schad L, Zollner F Diagnostics (Basel). 2022; 12(8).

PMID: 36010205 PMC: 9406826. DOI: 10.3390/diagnostics12081854.


Recent advances in imaging techniques of renal masses.

Aggarwal A, Das C, Sharma S World J Radiol. 2022; 14(6):137-150.

PMID: 35978979 PMC: 9258310. DOI: 10.4329/wjr.v14.i6.137.


The Role of Arterial Spin Labeling Functional MRI in Assessing Perfusion Impairment of Renal Allografts: A Systematic Review.

Chhabra J, Karwarker G, Rajamanuri M, Reddy Maligireddy A, Dai E, Chahal M Cureus. 2022; 14(5):e25428.

PMID: 35769679 PMC: 9236280. DOI: 10.7759/cureus.25428.


Non-invasive Assessment of Subclinical Renal Parenchymal Changes in Chronic Hepatitis B Virus By T1 Mapping Magnetic Resonance Imaging.

Ozkok S, Buz A, Erdemli S, Sasak Kuzgun G, Aslan A Balkan Med J. 2022; 39(2):115-120.

PMID: 35330558 PMC: 8941224. DOI: 10.4274/balkanmedj.galenos.2021.2021-6-133.


References
1.
Boss A, Martirosian P, Claussen C, Schick F . Quantitative ASL muscle perfusion imaging using a FAIR-TrueFISP technique at 3.0 T. NMR Biomed. 2006; 19(1):125-32. DOI: 10.1002/nbm.1013. View

2.
Schwenzer N, Schraml C, Martirosian P, Boss A, Claussen C, Schick F . MR measurement of blood flow in the parotid gland without contrast medium: a functional study before and after gustatory stimulation. NMR Biomed. 2007; 21(6):598-605. DOI: 10.1002/nbm.1231. View

3.
Sadowski E, Fain S, Alford S, Korosec F, Fine J, Muehrer R . Assessment of acute renal transplant rejection with blood oxygen level-dependent MR imaging: initial experience. Radiology. 2005; 236(3):911-9. DOI: 10.1148/radiol.2363041080. View

4.
Martirosian P, Klose U, Mader I, Schick F . FAIR true-FISP perfusion imaging of the kidneys. Magn Reson Med. 2004; 51(2):353-61. DOI: 10.1002/mrm.10709. View

5.
Baxter G . Ultrasound of renal transplantation. Clin Radiol. 2002; 56(10):802-18. DOI: 10.1053/crad.2001.0812. View