» Articles » PMID: 19724513

Binocular Adaptive Optics Visual Simulator

Overview
Journal Opt Lett
Specialty Ophthalmology
Date 2009 Sep 3
PMID 19724513
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

A binocular adaptive optics visual simulator is presented. The instrument allows for measuring and manipulating ocular aberrations of the two eyes simultaneously, while the subject performs visual testing under binocular vision. An important feature of the apparatus consists on the use of a single correcting device and wavefront sensor. Aberrations are controlled by means of a liquid-crystal-on-silicon spatial light modulator, where the two pupils of the subject are projected. Aberrations from the two eyes are measured with a single Hartmann-Shack sensor. As an example of the potential of the apparatus for the study of the impact of the eye's aberrations on binocular vision, results of contrast sensitivity after addition of spherical aberration are presented for one subject. Different binocular combinations of spherical aberration were explored. Results suggest complex binocular interactions in the presence of monochromatic aberrations. The technique and the instrument might contribute to the better understanding of binocular vision and to the search for optimized ophthalmic corrections.

Citing Articles

Head-mounted adaptive optics visual simulator.

Soomro S, Sager S, Paniagua-Diaz A, Prieto P, Artal P Biomed Opt Express. 2024; 15(2):608-623.

PMID: 38404335 PMC: 10890873. DOI: 10.1364/BOE.506858.


Accommodation through simulated multifocal optics.

Vedhakrishnan S, de Castro A, Vinas M, Aissati S, Marcos S Biomed Opt Express. 2023; 13(12):6695-6710.

PMID: 36589586 PMC: 9774842. DOI: 10.1364/BOE.473595.


Adaptive optics visual simulators: a review of recent optical designs and applications [Invited].

Marcos S, Artal P, Atchison D, Hampson K, Legras R, Lundstrom L Biomed Opt Express. 2023; 13(12):6508-6532.

PMID: 36589577 PMC: 9774875. DOI: 10.1364/BOE.473458.


Evaluating the effect of ocular aberrations on the simulated performance of a new refractive IOL design using adaptive optics.

Lago C, de Castro A, Benedi-Garcia C, Aissati S, Marcos S Biomed Opt Express. 2023; 13(12):6682-6694.

PMID: 36589555 PMC: 9774854. DOI: 10.1364/BOE.473573.


Advanced Optical Wavefront Technologies to Improve Patient Quality of Vision and Meet Clinical Requests.

Vacalebre M, Frison R, Corsaro C, Neri F, Conoci S, Anastasi E Polymers (Basel). 2022; 14(23).

PMID: 36501713 PMC: 9741482. DOI: 10.3390/polym14235321.