» Articles » PMID: 19441486

A Gold Nanoparticle-based Microfluidic Protein Chip for Tumor Markers

Overview
Specialty Biotechnology
Date 2009 May 16
PMID 19441486
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

A cancer protein chip has been developed incorporating with signal amplification technology based on gold nanoparticles (AuNPs) and microfluidic technology. The chip was a reversed phase one that deposited the target proteins directly onto chip surface. At first, a tumor marker protein, carcinoma embryonic antigen (CEA), was captured on the chip with the help of first layer microfluidic channel. Then, monoclonal antibody was reacted with the CEA through the second layer microfluidic channel at upright direction against the first layer. In the end, AuNPs labeled secondary antibody and silver enhancement regent were added to creating positive or negative signals in crossed areas, depending on the amounts of tumor marker protein. Using the protein chip based on nanotechnology, we could detect CEA at a wide range of concentration (5-50,000 ng/mL) and also had high sensitivity (LOD < 1 pM). Because of its quick detection procedure and no need for high-cost instruments, the protein chip showed potential use for point-of-care (POC) diagnostics.

Citing Articles

Design and fabrication of a microfluidic chip to detect tumor markers.

Sun C, You H, Gao N, Chang J, Gao Q, Xie Y RSC Adv. 2022; 10(65):39779-39785.

PMID: 35515361 PMC: 9057392. DOI: 10.1039/d0ra06693a.


Point-of-care testing in the diagnosis of gastrointestinal cancers: current technology and future directions.

Huddy J, Ni M, Markar S, Hanna G World J Gastroenterol. 2015; 21(14):4111-20.

PMID: 25892860 PMC: 4394071. DOI: 10.3748/wjg.v21.i14.4111.


Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection.

Fu E, Liang T, Spicar-Mihalic P, Houghtaling J, Ramachandran S, Yager P Anal Chem. 2012; 84(10):4574-9.

PMID: 22537313 PMC: 3366194. DOI: 10.1021/ac300689s.


Enhanced sensitivity of lateral flow tests using a two-dimensional paper network format.

Fu E, Liang T, Houghtaling J, Ramachandran S, Ramsey S, Lutz B Anal Chem. 2011; 83(20):7941-6.

PMID: 21936486 PMC: 3219509. DOI: 10.1021/ac201950g.


Chemical signal amplification in two-dimensional paper networks.

Fu E, Kauffman P, Lutz B, Yager P Sens Actuators B Chem. 2010; 149(1):325-328.

PMID: 20706615 PMC: 2917776. DOI: 10.1016/j.snb.2010.06.024.