Assessing Indoor Air Exposures Using Passive Sampling with Bioanalytical Methods for Estrogenicity and Aryl Hydrocarbon Receptor Activity
Overview
Authors
Affiliations
Passive air sampling was undertaken using polyurethane foam passive air samplers at three types of locations, including indoors (six offices) at buildings in the central business district (CBD) and at a private suburban home (indoor and outdoor) located 9 km from the CBD in Brisbane, Queensland, Australia. Estrogenic (E-SCREEN--MCF7-BOS) and aryl hydrocarbon receptor (AhR) (CAFLUX--H4G1.1c2) activity were assessed for samples collected from each of these locations. The samples were tested either as crude extracts ("untreated") or were subjected to H2SO4 silica gel ("treated") for each location in order to determine whether chemicals, which are not resistant to this treatment like polycyclic aromatic hydrocarbons, potentially account for the observed activity. In most cases, H2SO4 treatment resulted in a statistically significant reduction of potency for both endpoints, suggesting that chemicals less resistant to treatment may be responsible for much of the detected biological activity in these locations. Estrogenic potency measurements (<0.22-185 pg m(-3)) were highest in the indoor offices, followed by the indoor suburban home and finally the outdoor suburban home (which was not estrogenic). Total AhR activity for crude extracts (1.3-10 pg m(-3)) however was highest for the outdoor suburban home site. Levels of polycyclic aromatic hydrocarbons were monitored indoors and outdoors at the suburban home. At that location, polycyclic aromatic hydrocarbon air concentrations were on average approximately two times higher outdoor than indoor, while AhR potency was five times higher outdoor than indoor. No significant correlation was found between the estrogenic and AhR activity (P = 0.88) for the sites in this study.
Pyambri M, Lacorte S, Jaumot J, Bedia C Environ Sci Technol. 2023; 57(49):20532-20541.
PMID: 38035630 PMC: 10720387. DOI: 10.1021/acs.est.3c07573.
Indoor Exposure to Selected Air Pollutants in the Home Environment: A Systematic Review.
Vardoulakis S, Giagloglou E, Steinle S, Davis A, Sleeuwenhoek A, Galea K Int J Environ Res Public Health. 2020; 17(23).
PMID: 33276576 PMC: 7729884. DOI: 10.3390/ijerph17238972.
Croes K, Van Den Heuvel R, Van den Bril B, Staelens J, Denison M, Van Langenhove K Environ Res. 2016; 150:66-72.
PMID: 27257826 PMC: 7932495. DOI: 10.1016/j.envres.2016.05.044.
Croes K, Debaillie P, Van den Bril B, Staelens J, Vandermarken T, Van Langenhove K Chemosphere. 2015; 144:392-8.
PMID: 26383266 PMC: 7976781. DOI: 10.1016/j.chemosphere.2015.09.020.
Effect-based assessment of passive air samples from four countries in Eastern Europe.
Ersekova A, Hilscherova K, Klanova J, Giesy J, Novak J Environ Monit Assess. 2014; 186(6):3905-16.
PMID: 24532343 DOI: 10.1007/s10661-014-3667-z.