» Articles » PMID: 21552507

Effect Based Monitoring of Seasonal Ambient Air Exposures in Australia Sampled by PUF Passive Air Samplers

Overview
Date 2011 May 10
PMID 21552507
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

There has been relatively little bioanalytical effect based monitoring conducted using samples derived from polyurethane foam (PUF) passive air samplers. Combining these techniques may provide a more convenient and cost effective means of monitoring the potential for biological effects resulting from exposure to complex mixtures in a range of scenarios. Seasonal polycyclic aromatic hydrocarbon (PAH) levels were monitored at sites around Australia using direct chemical analysis. In addition, both indirect acting genotoxicity (umuC assay) and aryl hydrocarbon receptor (AhR) activity (chemically activated fluorescent gene expression [CAFLUX assay]), which are effects potentially relevant to subsequent carcinogenesis for these compounds, were measured. The levels of PAHs as well as genotoxicity and AhR activity were all higher in winter compared to summer and for sites in urban capital cities compared to other locations. Statistically significant relationships were found between the levels of PAHs and both genotoxicity and AhR activity. The dominant contributors to the total AhR activity, were found to be for compounds which are not resistant to H(2)SO(4)/silica gel treatment and were relatively rapidly metabolised that is consistent with a PAH type response. Relative potency estimates for individual PAHs determined for the first time on the CAFLUX assay were used to estimate the proportion of total AhR activity (≤ 3.0%) accounted by PAHs monitored. Observed responses are thus largely due to non-quantified AhR active compounds.

Citing Articles

Cytotoxic and Transcriptomic Effects in Avian Hepatocytes Exposed to a Complex Mixture from Air Samples, and Their Relation to the Organic Flame Retardant Signature.

Ha K, Xia P, Crump D, Saini A, Harner T, OBrien J Toxics. 2021; 9(12).

PMID: 34941758 PMC: 8704741. DOI: 10.3390/toxics9120324.


Aryl hydrocarbon receptor-mediated activity of gas-phase ambient air derived from passive sampling and an in vitro bioassay.

McDonough C, Franks D, Hahn M, Lohmann R Environ Toxicol Chem. 2019; 38(4):748-759.

PMID: 30648756 PMC: 6467651. DOI: 10.1002/etc.4361.


Assessment of estrogenic and androgenic activity in PM10 air samples from an urban, industrial and rural area in Flanders (Belgium) using the CALUX bioassay.

Croes K, Van Den Heuvel R, Van den Bril B, Staelens J, Denison M, Van Langenhove K Environ Res. 2016; 150:66-72.

PMID: 27257826 PMC: 7932495. DOI: 10.1016/j.envres.2016.05.044.


Monitoring PAHs in the petrochemical area of Tarragona County, Spain: comparing passive air samplers with lichen transplants.

Dominguez-Morueco N, Augusto S, Trabalon L, Pocurull E, Borrull F, Schuhmacher M Environ Sci Pollut Res Int. 2015; 24(13):11890-11900.

PMID: 26493300 DOI: 10.1007/s11356-015-5612-2.


Assessment of estrogenic activity in PM₁₀ air samples with the ERE-CALUX bioassay: Method optimization and implementation at an urban location in Flanders (Belgium).

Croes K, Debaillie P, Van den Bril B, Staelens J, Vandermarken T, Van Langenhove K Chemosphere. 2015; 144:392-8.

PMID: 26383266 PMC: 7976781. DOI: 10.1016/j.chemosphere.2015.09.020.


References
1.
Jaward F, Farrar N, Harner T, Sweetman A, Jones K . Passive air sampling of polycyclic aromatic hydrocarbons and polychlorinated naphthalenes across Europe. Environ Toxicol Chem. 2004; 23(6):1355-64. DOI: 10.1897/03-420. View

2.
Atkinson R, Arey J . Atmospheric chemistry of gas-phase polycyclic aromatic hydrocarbons: formation of atmospheric mutagens. Environ Health Perspect. 1994; 102 Suppl 4:117-26. PMC: 1566940. DOI: 10.1289/ehp.94102s4117. View

3.
Skarek M, Janosek J, cupr P, Kohoutek J, Novotna-Rychetska A, Holoubek I . Evaluation of genotoxic and non-genotoxic effects of organic air pollution using in vitro bioassays. Environ Int. 2007; 33(7):859-66. DOI: 10.1016/j.envint.2007.04.001. View

4.
Chaemfa C, Wild E, Davison B, Barber J, Jones K . A study of aerosol entrapment and the influence of wind speed, chamber design and foam density on polyurethane foam passive air samplers used for persistent organic pollutants. J Environ Monit. 2009; 11(6):1135-9. DOI: 10.1039/b823016a. View

5.
Anezaki K, Yamaguchi K, Takeuchi S, Iida M, Jin K, Kojima H . Application of a bioassay using DR-EcoScreen cells to the determination of dioxins in ambient air: a comparative study with HRGC-HRMS analysis. Environ Sci Technol. 2009; 43(19):7478-83. DOI: 10.1021/es901003b. View