» Articles » PMID: 19424315

Measurement and Imaging of Birefringence and Optic Axis Orientation by Phase Resolved Polarization Sensitive Optical Coherence Tomography

Overview
Journal Opt Express
Date 2009 May 9
PMID 19424315
Citations 99
Authors
Affiliations
Soon will be listed here.
Abstract

We present an improved method of polarization sensitive optical coherence tomography that enables measurement and imaging of backscattered intensity, birefringence, and fast optic axis orientation simultaneously with only one single A-scan per transverse measurement location. While intensity and birefringence data are obtained in a conventional way, the optic axis orientation is determined from the phase difference recorded in two orthogonal polarization channels. We report on accuracy and precision of the method by measuring birefringence and optic axis orientation of well defined polarization states in a technical object and present maps of birefringence and, what we believe for the first time, of optic axis orientation in biological tissue.

Citing Articles

Polarization-insensitive optical coherence tomography using pseudo-depolarized reference light for mitigating birefringence-related image artifacts.

Varaka M, Merkle C, May L, Worm S, Augustin M, Fanjul-Velez F J Biomed Opt. 2024; 29(11):116001.

PMID: 39502366 PMC: 11532802. DOI: 10.1117/1.JBO.29.11.116001.


Segmentation of choroidal area in optical coherence tomography images using a transfer learning-based conventional neural network: a focus on diabetic retinopathy and a literature review.

Saeidian J, Azimi H, Azimi Z, Pouya P, Asadigandomani H, Riazi-Esfahani H BMC Med Imaging. 2024; 24(1):281.

PMID: 39425019 PMC: 11488256. DOI: 10.1186/s12880-024-01459-2.


Visualization enhancement by PCA-based image fusion for skin burns assessment in polarization-sensitive OCT.

Xu J, Zhu M, Tang P, Li J, Gao K, Qiu H Biomed Opt Express. 2024; 15(7):4190-4205.

PMID: 39022536 PMC: 11249677. DOI: 10.1364/BOE.521399.


Insights into atypical segmental layer thicknesses and phase retardation in thick corneas using ultrahigh-resolution polarization-sensitive optical coherence tomography.

Patil R, Shetty R, Khamar P, Patel Y, Narasimhan R, Bhatkal A Eye Vis (Lond). 2024; 11(1):30.

PMID: 39004731 PMC: 11247896. DOI: 10.1186/s40662-024-00391-4.


An integrated model of the human cornea as a linear biaxial birefringent medium.

Sobczak M, Jozwik A, Kurzynowski P Sci Rep. 2024; 14(1):5077.

PMID: 38429419 PMC: 10907592. DOI: 10.1038/s41598-024-55800-4.