Abstract

Unlabelled: Reducing acquisition time may improve patient throughput, increase camera efficiency, and reduce costs; reducing acquisition time also increases image noise. Newly available software controls the effects of noise by maximum a posteriori reconstruction while maintaining resolution with resolution-recovery methods. This study compares half-time (HT) gated myocardial SPECT images processed with ordered-subset expectation maximization with resolution recovery (OSEM-RR) (with and without CT-based attenuation correction [AC]) with full-time (FT) images obtained with a standard clinical protocol and reconstructed with filtered backprojection (FBP) and OSEM (with and without AC).

Methods: A total of 212 patients (mean age, 57 y; age range, 27-86 y) underwent 1-d rest/stress (99m)Tc-tetrofosmin gated SPECT. FT (12.5 min, both rest and stress) and HT (rest, 7.5 min; stress, 6.0 min) images were acquired with low-dose CT for AC in 112 patients. HT acquisitions were processed with OSEM-RR (with and without AC) using software, and FT acquisitions were processed with FBP and OSEM (with and without AC). In another 100 patients, test-retest repeatability was assessed using 2 sets of FT images (FBP reconstruction) that were acquired one immediately after the other. Radiologists unaware of the acquisition and reconstruction protocols visually assessed all reconstructed images for summed stress, summed rest, and summed difference scores and regional wall motion using a 17-segment model. Automated analysis on gated SPECT was used to determine left ventricular volumes, ejection fraction, and dilation (end-diastolic volume, end-systolic volume, left ventricular ejection fraction, and transient ischemic dilation [TID]). A clinical diagnosis was also determined.

Results: All measurements resulted in significant correlations (P < 0.01) between the HT and FT images. The only significant difference in mean values was for OSEM-RR plus AC; this method led to an increase in TID by 4% over FT imaging. The concordance in the clinical diagnosis for HT versus FT was 106 to 112 (kappa = 0.88) for no AC and 102 to 106 (kappa = 0.91) for AC, similar to the repeatability of FT versus FT (98/100, kappa = 0.95).

Conclusion: HT images processed with the new algorithm provided a clinical diagnosis in concordance with that from FT images in 95% (no AC) to 96% (AC) of cases. This concordance is similar to the test-retest repeatability of FT imaging.

Citing Articles

Ultra high speed SPECT bone imaging enabled by a deep learning enhancement method: a proof of concept.

Pan B, Qi N, Meng Q, Wang J, Peng S, Qi C EJNMMI Phys. 2022; 9(1):43.

PMID: 35698006 PMC: 9192886. DOI: 10.1186/s40658-022-00472-0.


Optimization of Tc whole-body SPECT/CT image quality: A phantom study.

Alqahtani M, Willowson K, Constable C, Fulton R, Kench P J Appl Clin Med Phys. 2022; 23(4):e13528.

PMID: 35049129 PMC: 8992937. DOI: 10.1002/acm2.13528.


CT Attenuation correction and its impact on image quality of myocardial perfusion imaging in coronary artery disease: A systematic review.

Farrell C, Pinson J, Dennett A Asia Ocean J Nucl Med Biol. 2021; 9(1):31-38.

PMID: 33392347 PMC: 7701231. DOI: 10.22038/AOJNMB.2020.50692.1346.


Single-photon cardiac imaging in patients with cardiac implantable electrical devices.

Valzania C, Bonfiglioli R, Fallani F, Martignani C, Ziacchi M, Diemberger I J Nucl Cardiol. 2020; 29(2):633-641.

PMID: 33241474 DOI: 10.1007/s12350-020-02436-2.


Improving Diagnostic Accuracy in Low-Dose SPECT Myocardial Perfusion Imaging With Convolutional Denoising Networks.

Juan Ramon A, Yang Y, Pretorius P, Johnson K, King M, Wernick M IEEE Trans Med Imaging. 2020; 39(9):2893-2903.

PMID: 32167887 PMC: 9472754. DOI: 10.1109/TMI.2020.2979940.