» Articles » PMID: 19273481

Nipple Aspirate Fluid Collection, Related Factors and Relationship Between Carcinoembryonic Antigen in Nipple Aspirate Fluid and Breast Diseases in Women in Harbin, PRC

Overview
Date 2009 Mar 11
PMID 19273481
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

This study aimed to examine the factors related to the ability to obtain nipple aspirate fluids in Chinese women and to evaluate the diagnostic value of carcinoembryonic antigen (CEA) in nipple aspiration fluids. Cross-sectional and case-control studies were used to examine the factors associated with the ability to obtain nipple aspiration fluids. A matched case-control study was used to explore the association of CEA level in nipple aspiration fluids with breast disease. CEA level was log10-transformed to normalize the distribution. Univariate and multivariate logistic regression were adopted to analyze the variables in relation to obtaining fluid and the association of its CEA levels and breast diseases. Receiver operating characteristic curve was used to evaluate the value of CEA levels for the detection of breast disease. The nipple aspiration fluid collection rate was 34.24% (201 of 587). Multivariate logistic regression analysis results showed the following to be significantly associated with a greater ability to obtain nipple aspiration fluids: earlier age at menarche [odds ratio (OR), 2.61; 95% confidence interval (95% CI), 1.15-5.91], lactating>12 months (OR, 2.28; 95% CI, 1.44-3.60), wet-type ear wax (OR, 3.80; 95% CI, 2.39-6.02), and fatty diet (OR, 1.56; 95% CI, 1.02-2.39). CEA levels in nipple aspiration fluids of cancerous breasts were significantly higher than those from breasts with benign disease and healthy controls (ORadj, 5.39; P<0.01). However, the sensitivity of CEAs was 35.42% and the specificity was 85.42% whereas the CEA cutoff value was 307.61 ng/mL. The area under the receiver operating characteristic curve was 0.65. The nipple aspiration fluid collection rate in Chinese native women is lower compared to non-Asian-descendant women. CEA level does not seem to be a useful diagnostic tool for early cancer detection; it can only be used in conjugation with other methods.

Citing Articles

Early detection of breast cancer through the diagnosis of Nipple Aspirate Fluid (NAF).

Pant A, Anjankar A, Shende S, Dhok A, Jha R, Manglaram A Clin Proteomics. 2024; 21(1):45.

PMID: 38943056 PMC: 11212179. DOI: 10.1186/s12014-024-09495-4.


Nipple Aspirate Fluid at a Glance.

Patuleia S, Suijkerbuijk K, van der Wall E, van Diest P, Moelans C Cancers (Basel). 2022; 14(1).

PMID: 35008326 PMC: 8750428. DOI: 10.3390/cancers14010159.


High-Throughput Proteomic Profiling of Nipple Aspirate Fluid from Breast Cancer Patients Compared with Non-Cancer Controls: A Step Closer to Clinical Feasibility.

George A, Shaheed S, Sutton C J Clin Med. 2021; 10(11).

PMID: 34064148 PMC: 8196703. DOI: 10.3390/jcm10112243.


Evaluation of nipple aspirate fluid as a diagnostic tool for early detection of breast cancer.

Sadr-Ul Shaheed , Tait C, Kyriacou K, Linforth R, Salhab M, Sutton C Clin Proteomics. 2018; 15:3.

PMID: 29344009 PMC: 5763528. DOI: 10.1186/s12014-017-9179-4.


Different Levels of CEA, CA153 and CA125 in Milk and Benign and Malignant Nipple Discharge.

Zhao S, Mei Y, Wang J, Zhang K, Ma R PLoS One. 2016; 11(6):e0157639.

PMID: 27327081 PMC: 4915693. DOI: 10.1371/journal.pone.0157639.