» Articles » PMID: 19164489

Aberration-corrected ADF-STEM Depth Sectioning and Prospects for Reliable 3D Imaging in S/TEM

Overview
Specialty Radiology
Date 2009 Jan 24
PMID 19164489
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

The short depth of focus of aberration-corrected scanning transmission electron microscopes (STEMs) could potentially enable 3D reconstruction of nanomaterials through acquisition of a through-focal series. However, the contrast transfer function of annular dark-field (ADF)-STEM depth sectioning has a missing-cone problem similar to that of tilt-series tomography. The elongation as a function of the probe-forming angle is found to be (square root of 3/2) x 1/alphamax. For existing aberration-corrected STEMs operated at optimal imaging conditions, the elongation factor for depth sectioning is larger than 30. This large elongation factor results in highly distorted shapes of 3D objects and unexpected artifacts due to the loss of information. Depth-sectioning experiments using a 33-mrad 100 keV C(5)-corrected aberration-corrected STEM demonstrate the elongation effect and the missing-cone problem in real and reciprocal space. The performance limits of different S/TEM-based imaging modes are compared. There is a missing cone of information for bright-field S/TEM, ADF-STEM, hollow-cone ADF-STEM and coherent scanning confocal electron microscopy (SCEM). Only incoherent SCEM fills the missing cone.

Citing Articles

Sub-nanometer depth resolution and single dopant visualization achieved by tilt-coupled multislice electron ptychography.

Dong Z, Zhang Y, Chiu C, Lu S, Zhang J, Liu Y Nat Commun. 2025; 16(1):1219.

PMID: 39890786 PMC: 11785980. DOI: 10.1038/s41467-025-56499-1.


Determination of atomic vacancies in InAs/GaSb strained-layer superlattices by atomic strain.

Kim H, Meng Y, Kwon J, Rouviere J, Zuo J IUCrJ. 2018; 5(Pt 1):67-72.

PMID: 29354272 PMC: 5755578. DOI: 10.1107/S2052252517016219.


Tilt-less 3-D electron imaging and reconstruction of complex curvilinear structures.

Oveisi E, Letouzey A, Alexander D, Jeangros Q, Schaublin R, Lucas G Sci Rep. 2017; 7(1):10630.

PMID: 28878280 PMC: 5587565. DOI: 10.1038/s41598-017-07537-6.


Electron Tomography: A Three-Dimensional Analytic Tool for Hard and Soft Materials Research.

Ercius P, Alaidi O, Rames M, Ren G Adv Mater. 2015; 27(38):5638-63.

PMID: 26087941 PMC: 4710474. DOI: 10.1002/adma.201501015.


Optimized deconvolution for maximum axial resolution in three-dimensional aberration-corrected scanning transmission electron microscopy.

Ramachandra R, de Jonge N Microsc Microanal. 2011; 18(1):218-28.

PMID: 22152090 PMC: 3387366. DOI: 10.1017/S1431927611012347.