» Articles » PMID: 19110368

Temporal and Spatial Detection of HIFU-induced Inertial and Hot-vapor Cavitation with a Diagnostic Ultrasound System

Overview
Specialty Radiology
Date 2008 Dec 27
PMID 19110368
Citations 47
Authors
Affiliations
Soon will be listed here.
Abstract

The onset and presence of inertial cavitation and near-boiling temperatures in high-intensity focused ultrasound (HIFU) therapy have been identified as important indicators of energy deposition for therapy guidance. Passive cavitation detection is commonly used to detect bubble emissions, where a fixed-focus single-element acoustic transducer is typically used as a passive cavitation detector (PCD). This technique is suboptimal for clinical applications, because most PCD transducers are tightly focused and afford limited spatial coverage of the HIFU focal region. A Terason 2000 Ultrasound System was used as a PCD array to expand the spatial detection region for cavitation by operating in passive mode, obtaining the radiofrequency signals corresponding to each scan line and filtering the contribution from scattering of the HIFU signal harmonics. This approach allows for spatially resolved detection of both inertial and stable cavitation throughout the focal region. Measurements with the PCD array during sonication with a 1.1-MHz HIFU source in tissue phantoms were compared with single-element PCD and thermocouple sensing. Stable cavitation signals at the harmonics and superharmonics increased in a threshold fashion for temperatures >90 degrees C, an effect attributed to high vapor pressure in the cavities. Incorporation of these detection techniques in a diagnostic ultrasound platform could result in a powerful tool for improving HIFU guidance and treatment.

Citing Articles

Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update.

Bader K, Padilla F, Haworth K, Ellens N, Dalecki D, Miller D J Ultrasound Med. 2024; 44(3):381-433.

PMID: 39526313 PMC: 11796337. DOI: 10.1002/jum.16611.


Three-dimensional super resolution ultrasound imaging with a multi-frequency hemispherical phased array.

Deng L, Lea-Banks H, Jones R, OReilly M, Hynynen K Med Phys. 2023; 50(12):7478-7497.

PMID: 37702919 PMC: 10872837. DOI: 10.1002/mp.16733.


Diameter-dependent assessment of microvascular leakage following ultrasound-mediated blood-brain barrier opening.

Katz S, Gattegno R, Peko L, Zarik R, Hagani Y, Ilovitsh T iScience. 2023; 26(6):106965.

PMID: 37378309 PMC: 10291464. DOI: 10.1016/j.isci.2023.106965.


Passive Cavitation Imaging Artifact Reduction Using Data-Adaptive Spatial Filtering.

Haworth K, Salido N, Lafond M, Escudero D, Holland C IEEE Trans Ultrason Ferroelectr Freq Control. 2023; 70(6):498-509.

PMID: 37018086 PMC: 10335845. DOI: 10.1109/TUFFC.2023.3264832.


Monitoring cavitation dynamics evolution in tissue mimicking hydrogels for repeated exposures via acoustic cavitation emissions.

Haskell S, Lu N, Stocker G, Xu Z, Sukovich J J Acoust Soc Am. 2023; 153(1):237.

PMID: 36732269 PMC: 10162839. DOI: 10.1121/10.0016849.