» Articles » PMID: 19104805

Magnetic Resonance Imaging Methodology

Overview
Date 2008 Dec 24
PMID 19104805
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Magnetic resonance (MR) methods are non-invasive techniques to provide detailed, multi-parametric information on human anatomy, function and metabolism. Sensitivity, specificity, spatial and temporal resolution may, however, vary depending on hardware (e.g., field strength, gradient strength and speed) and software (optimised measurement protocols and parameters for the various techniques). Furthermore, multi-modality imaging may enhance specificity to better characterise complex disease patterns.

Objective: Positron emission tomography (PET) is an interesting, largely complementary modality, which might be combined with MR. Despite obvious advantages, combining these rather different physical methods may also pose challenging problems. At this early stage, it seems that PET quality may be preserved in the magnetic field and, if an adequate detector material is used for the PET, MR sensitivity should not be significantly degraded. Again, this may vary for the different MR techniques, whereby functional and metabolic MR is more susceptible than standard anatomical imaging.

Discussion: Here we provide a short introduction to MR basics and MR techniques, also discussing advantages, artefacts and problems when MR hardware and PET detectors are combined. In addition to references for more detailed descriptions of MR fundamentals and applications, we provide an early outlook on this novel and exciting multi-modality approach to PET/MR.

Citing Articles

Automatic Adaptive Algorithm for Delineation of Cerebral-Spinal Fluid Regions for Non-contrast Magnetic Resonance Imaging Volumetry and Cisternography in Mice.

Gomolka R Bio Protoc. 2025; 15(1):e5148.

PMID: 39803313 PMC: 11717714. DOI: 10.21769/BioProtoc.5148.


MRI-Driven Alzheimer's Disease Diagnosis Using Deep Network Fusion and Optimal Selection of Feature.

Ali M, Hussain S, Khalid M, Farrash M, Lahza H, Zafar A Bioengineering (Basel). 2024; 11(11).

PMID: 39593736 PMC: 11591117. DOI: 10.3390/bioengineering11111076.


Enhancing Alzheimer's disease diagnosis and staging: a multistage CNN framework using MRI.

Ali M, Kim K, Khalid M, Farrash M, Zafar A, Lee S Front Psychiatry. 2024; 15:1395563.

PMID: 38979503 PMC: 11228270. DOI: 10.3389/fpsyt.2024.1395563.


The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis.

Yao K, Xie Y, Xia L, Wei S, Yu W, Shen G Diagnostics (Basel). 2023; 13(14).

PMID: 37510103 PMC: 10377994. DOI: 10.3390/diagnostics13142360.


Imaging of Gastrointestinal Tract Ailments.

Sun B, Liu J, Li S, Lovell J, Zhang Y J Imaging. 2023; 9(6).

PMID: 37367463 PMC: 10299193. DOI: 10.3390/jimaging9060115.


References
1.
Le Bihan D, Poupon C, Amadon A, Lethimonnier F . Artifacts and pitfalls in diffusion MRI. J Magn Reson Imaging. 2006; 24(3):478-88. DOI: 10.1002/jmri.20683. View

2.
Mountford C, Lean C, Malycha P, Russell P . Proton spectroscopy provides accurate pathology on biopsy and in vivo. J Magn Reson Imaging. 2006; 24(3):459-77. DOI: 10.1002/jmri.20668. View

3.
Schmidt G, Haug A, Schoenberg S, Reiser M . Whole-body MRI and PET-CT in the management of cancer patients. Eur Radiol. 2006; 16(6):1216-25. DOI: 10.1007/s00330-006-0183-8. View

4.
Le Bihan D, Mangin J, Poupon C, Clark C, Pappata S, Molko N . Diffusion tensor imaging: concepts and applications. J Magn Reson Imaging. 2001; 13(4):534-46. DOI: 10.1002/jmri.1076. View

5.
Ruehm S, Goyen M, Barkhausen J, Kroger K, Bosk S, Ladd M . Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet. 2001; 357(9262):1086-91. DOI: 10.1016/S0140-6736(00)04261-6. View