» Articles » PMID: 19077907

Experimental Validation of Peptide Immunohistochemistry Controls

Overview
Date 2008 Dec 17
PMID 19077907
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Peptide immunohistochemistry (IHC) controls are a new quality control format for verifying proper IHC assay performance, offering advantages in high throughput automated manufacture and standardization. We previously demonstrated that formalin-fixed peptide epitopes, covalently attached to glass microscope slides, behaved (immunochemically) in a similar fashion to the native protein in tissue sections. To convert this promising idea into a practical clinical laboratory quality control tool, we tested the hypothesis that the quality assurance information provided by peptide IHC controls accurately reflects IHC staining performance among a diverse group of clinical laboratories. To test the hypothesis, we first designed and built an instrument for reproducibly printing the controls on microscope slides and a simple software program to measure the color intensity of stained controls. Automated printing of peptide spots was reproducible, with coefficients of variation of 4% to 8%. Moreover, the peptide controls were stable at <or=4 degrees C for at least 7 months, the longest time duration we tested. A national study of 109 participating clinical laboratories demonstrated a good correlation between a laboratory's ability to properly stain formalin-fixed peptide controls to their ability in properly staining a 3+ HER-2 formalin-fixed tissue section mounted on the same slide (r=0.87). Therefore, peptide IHC controls accurately reflect the analytical component of an IHC stain, including antigen retrieval. Besides its use in proficiency survey testing, we also demonstrate the feasibility of applying peptide IHC controls for verifying intralaboratory IHC staining consistency, using Levy-Jennings charting.

Citing Articles

Quantitative assessment of H&E staining for pathology: development and clinical evaluation of a novel system.

Dunn C, Brettle D, Cockroft M, Keating E, Revie C, Treanor D Diagn Pathol. 2024; 19(1):42.

PMID: 38395890 PMC: 10885446. DOI: 10.1186/s13000-024-01461-w.


Methods for preparing tissue microarray slides using xenografts with different levels of HER2 expression to standardize HER2 detection.

Yorozu K, Kurasawa M, Iino Y, Nakamura Y, Hashizume K, Harada N Pathol Int. 2022; 73(1):39-44.

PMID: 36398869 PMC: 10100237. DOI: 10.1111/pin.13288.


Synthetic Antigen Gels as Practical Controls for Standardized and Quantitative Immunohistochemistry.

Hotzel K, Havnar C, Ngu H, Rost S, Liu S, Rangell L J Histochem Cytochem. 2019; 67(5):309-334.

PMID: 30879407 PMC: 6495489. DOI: 10.1369/0022155419832002.


Standardizing Immunohistochemistry: A New Reference Control for Detecting Staining Problems.

Sompuram S, Vani K, Tracey B, Kamstock D, Bogen S J Histochem Cytochem. 2015; 63(9):681-90.

PMID: 25940339 PMC: 4804728. DOI: 10.1369/0022155415588109.


Standardization of negative controls in diagnostic immunohistochemistry: recommendations from the international ad hoc expert panel.

Torlakovic E, Francis G, Garratt J, Gilks B, Hyjek E, Ibrahim M Appl Immunohistochem Mol Morphol. 2014; 22(4):241-52.

PMID: 24714041 PMC: 4206554. DOI: 10.1097/PAI.0000000000000069.


References
1.
Sompuram S, Vani K, Hafer L, Bogen S . Antibodies immunoreactive with formalin-fixed tissue antigens recognize linear protein epitopes. Am J Clin Pathol. 2006; 125(1):82-90. View

2.
Sompuram S, Vani K, Messana E, Bogen S . A molecular mechanism of formalin fixation and antigen retrieval. Am J Clin Pathol. 2004; 121(2):190-9. DOI: 10.1309/BRN7-CTX1-E84N-WWPL. View

3.
Dei Tos A, Ellis I . Assessing epidermal growth factor receptor expression in tumours: what is the value of current test methods?. Eur J Cancer. 2005; 41(10):1383-92. DOI: 10.1016/j.ejca.2005.03.018. View

4.
Sompuram S, Vani K, Bogen S . A molecular model of antigen retrieval using a peptide array. Am J Clin Pathol. 2006; 125(1):91-8. View

5.