Evaluation of Noninvasive Methods to Assess Wave Reflection and Pulse Transit Time from the Pressure Waveform Alone

Overview
Journal Hypertension
Date 2008 Dec 17
PMID 19075098
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

Accurate quantification of pressure wave reflection requires separation of pressure in forward and backward components to calculate the reflection magnitude as the ratio of the amplitudes backward and forward pressure. To do so, measurement of aortic flow in addition to the pressure wave is mandatory, a limitation that can be overcome by replacing the unknown flow wave by an (uncalibrated) triangular estimate. Another extended application of this principle is the derivation of aortic pulse transit time from a single pulse recording. We verified these approximation techniques for reflection magnitude and transit time using carotid pressure and aortic flow waveforms measured noninvasively in the Asklepios Study (>2500 participants; 35 to 55 years of age). A triangular flow approximation using timing information from the measured aortic flow waveform yielded moderate agreement between reference and estimated reflection magnitude (R(2)=0.55). Approximating the flow by a more physiological waveform significantly improved these results (R(2)=0.74). Aortic transit time was assessed using pressure and measured or approximated flow waveforms, and results were compared with carotid-femoral transit times measured by Doppler ultrasound. Agreement between estimated and reference transit times was moderate (R(2)<0.29). Both for reflection magnitude and transit time, agreement between reference and approximated values further decreased when the approximated flow waveform was obtained using timing information from the pressure waveform. We conclude that, in our Asklepios population, results from pressure-based approximative methods to derive reflection magnitude or aortic pulse transit time differ substantially from the values obtained when using both measured pressure and flow information.

Citing Articles

Intervention, improved prevention, imaging, inflammation, and innovation: the five I's cardiovascular highlights in 2024.

Back M, Banach M, Braunschweig F, De Rosa S, Flachskampf F, Kahan T Eur Heart J Open. 2025; 5(1):oeaf015.

PMID: 40041611 PMC: 11878772. DOI: 10.1093/ehjopen/oeaf015.


Estimation of pulse wave analysis indices from invasive arterial blood pressure only for a clinical assessment of wave reflection in a 5-day septic animal experiment.

Guberti D, Ferrario M, Carrara M Med Biol Eng Comput. 2025; .

PMID: 40014240 DOI: 10.1007/s11517-025-03328-8.


Assessing pressure wave components for aortic stiffness monitoring through spectral regression learning.

Aghilinejad A, Gharib M Eur Heart J Open. 2024; 4(3):oeae040.

PMID: 38863521 PMC: 11165314. DOI: 10.1093/ehjopen/oeae040.


Development of hypertension models for lung cancer screening cohorts using clinical and thoracic aorta imaging factors.

Yang J, Yu J, Wang Y, Liao M, Ji Y, Li X Sci Rep. 2024; 14(1):6862.

PMID: 38514739 PMC: 10957886. DOI: 10.1038/s41598-024-57396-1.


Superiority of a Representative MRI Flow Waveform over Doppler Ultrasound for Aortic Wave Reflection Assessment in Children and Adolescents With/Without a History of Heart Disease.

Mynard J, Kowalski R, Harrington H, Kondiboyina A, Smolich J, Cheung M Ann Biomed Eng. 2023; 51(12):2772-2784.

PMID: 37561232 PMC: 10632254. DOI: 10.1007/s10439-023-03339-2.