Acoustic characterization of high intensity focused ultrasound (HIFU) fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2 MHz transducer with an aperture and focal length of 4.4 cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24,000 W/cm(2). The inputs to a Khokhlov-Zabolotskaya-Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80 MPa and peak negative pressures up to 15 MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000 W/cm(2), lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100 MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields.

Citing Articles

Precision oncology: The role of minimally-invasive ablation therapy in the management of solid organ tumors.

Fazlollahi F, Makary M World J Radiol. 2025; 17(1):98618.

PMID: 39876886 PMC: 11755905. DOI: 10.4329/wjr.v17.i1.98618.


Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update.

Bader K, Padilla F, Haworth K, Ellens N, Dalecki D, Miller D J Ultrasound Med. 2024; 44(3):381-433.

PMID: 39526313 PMC: 11796337. DOI: 10.1002/jum.16611.


Histotripsy-Induced Bactericidal Activity Correlates to Size of Cavitation Cloud In Vitro.

Ambekar P, Wang Y, Khokhlova T, Khokhlova T, Thomas G, Thomas G IEEE Trans Ultrason Ferroelectr Freq Control. 2024; 71:1868-1878.

PMID: 39383065 PMC: 11875908. DOI: 10.1109/TUFFC.2024.3476438.


Revealing physical interactions of ultrasound waves with the body through photoelasticity imaging.

Maxwell A Opt Lasers Eng. 2024; 181.

PMID: 39219742 PMC: 11361005. DOI: 10.1016/j.optlaseng.2024.108361.


Focused ultrasound as a treatment modality for gliomas.

Nwafor D, Obiri-Yeboah D, Fazad F, Blanks W, Mut M Front Neurol. 2024; 15:1387986.

PMID: 38813245 PMC: 11135048. DOI: 10.3389/fneur.2024.1387986.


References
1.
Yang X, Cleveland R . Time domain simulation of nonlinear acoustic beams generated by rectangular pistons with application to harmonic imaging. J Acoust Soc Am. 2005; 117(1):113-23. DOI: 10.1121/1.1828671. View

2.
Parsons J, Cain C, Fowlkes J . Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields. J Acoust Soc Am. 2006; 119(3):1432-40. DOI: 10.1121/1.2166708. View

3.
Radulescu E, Lewin P, Goldstein A, Nowicki A . Hydrophone spatial averaging corrections from 1 to 40 MHz. IEEE Trans Ultrason Ferroelectr Freq Control. 2002; 48(6):1575-80. DOI: 10.1109/58.971709. View

4.
Dalecki D, Carstensen E, Parker K, Bacon D . Absorption of finite amplitude focused ultrasound. J Acoust Soc Am. 1991; 89(5):2435-47. DOI: 10.1121/1.400976. View

5.
Hynynen K, Clement G . Clinical applications of focused ultrasound-the brain. Int J Hyperthermia. 2007; 23(2):193-202. DOI: 10.1080/02656730701200094. View