Abstract

A chemiluminescence (CL) biosensor on a chip coupled to microfluidic system is described in this paper. The CL biosensor measured 25x45x5 mm in dimension, was readily produced in analytical laboratory. Glucose oxidase (GOD) was immobilized onto controlled-pore glass (CPG) via glutaraldehyde activation and packed into a reservoir. The analytical reagents, including luminol and ferricyanide, were electrostatically co-immobilized on an anion-exchange resin. The most characteristic of the biosensor was to introduce the air as the carrier flow in stead of the common solution carrier for the first. The glucose was sensed by the CL reaction between hydrogen peroxide produced from the enzymatic reaction and CL reagents, which were released from the anion-exchange resin. The proposed method has been successfully applied to the determination of glucose in human serum. The linear range of the glucose concentration was 1.1-110 mM and the detection limit was 0.1 mM (3sigma).

Citing Articles

Electrochemical Sensing of Glucose Using Glucose Oxidase/PEDOT:4-Sulfocalix [4]arene/MXene Composite Modified Electrode.

Murugan P, Annamalai J, Atchudan R, Govindasamy M, Nallaswamy D, Ganapathy D Micromachines (Basel). 2022; 13(2).

PMID: 35208428 PMC: 8877456. DOI: 10.3390/mi13020304.


Developing a CNT-SPE Sensing Platform Based on Green Synthesized AuNPs, Using sp.

Gonzalez-Fuentes F, Molina G, Silva R, Lopez-Miranda J, Esparza R, Hernandez-Martinez A Sensors (Basel). 2020; 20(21).

PMID: 33121053 PMC: 7662439. DOI: 10.3390/s20216108.


Flow biosensing and sampling in indirect electrochemical detection.

Lamberti F, Luni C, Zambon A, Serra P, Giomo M, Elvassore N Biomicrofluidics. 2012; 6(2):24114-2411413.

PMID: 22655022 PMC: 3360726. DOI: 10.1063/1.4705368.


A magnetically active microfluidic device for chemiluminescence bioassays.

Zheng Y, Zhao S, Liu Y Analyst. 2011; 136(14):2890-2.

PMID: 21647506 PMC: 3634340. DOI: 10.1039/c1an15307b.


Optical flow-through sensor for the determination of norfloxacin based on emission of KMnO(4)-Na (2)SO (3)-Tb (3+) system.

Jeon C, Khan M, Lee S, Karim M, Lee H, Suh Y J Fluoresc. 2008; 18(5):843-51.

PMID: 18205029 DOI: 10.1007/s10895-008-0313-6.