Desai S, Naveen R, Goudanavar P, Gowthami B
Pharm Nanotechnol. 2023; 12(3):197-205.
PMID: 37680159
DOI: 10.2174/2211738511666230901160530.
Badugu R, Lakowicz J, Geddes C
Rev Fluoresc. 2021; 2005:363-397.
PMID: 33967658
PMC: 8101969.
DOI: 10.1007/0-387-23690-2_15.
Szmacinski H, Lakowicz J
Sens Actuators B Chem. 2021; 29(1-3):16-24.
PMID: 33867678
PMC: 8049533.
DOI: 10.1016/0925-4005(95)01658-9.
Murtaza Z, Tolosa L, Harms P, Lakowicz J
J Fluoresc. 2020; 12(2):187-192.
PMID: 32377061
PMC: 7202357.
DOI: 10.1023/A:1016800515030.
Di Cesare N, Lakowicz J
J Photochem Photobiol A Chem. 2020; 143(1):39-47.
PMID: 32025171
PMC: 7001379.
DOI: 10.1016/S1010-6030(01)00471-3.
Optical assay for glucose based on the luminescnence decay time of the long wavelength dye Cy5™.
Tolosa L, Malak H, Raob G, Lakowicz J
Sens Actuators B Chem. 2020; 45(2):93-99.
PMID: 31909583
PMC: 6938716.
DOI: 10.1016/S0925-4005(97)00275-X.
Tunable plasmonic glucose sensing based on the dissociation of Con A-aggregated dextran-coated gold colloids.
Aslan K, Lakowicz J, Geddes C
Anal Chim Acta. 2020; 517(1-2):139-144.
PMID: 31896834
PMC: 6939462.
DOI: 10.1016/j.aca.2004.04.060.
High Affinity Mannotetraose as an Alternative to Dextran in ConA Based Fluorescent Affinity Glucose Assay Due to Improved FRET Efficiency.
Locke A, Cummins B, Cote G
ACS Sens. 2017; 1(5):584-590.
PMID: 28529973
PMC: 5438212.
DOI: 10.1021/acssensors.5b00304.
A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring.
Badugu R, Lakowicz J, Geddes C
J Fluoresc. 2016; 13(5):371-374.
PMID: 27340364
PMC: 4915737.
DOI: 10.1023/A:1026103804104.
PEGylation of concanavalin A to improve its stability for an in vivo glucose sensing assay.
Locke A, Cummins B, Abraham A, Cote G
Anal Chem. 2014; 86(18):9091-7.
PMID: 25133655
PMC: 4165460.
DOI: 10.1021/ac501791u.
In vitro evaluation of fluorescence glucose biosensor response.
Aloraefy M, Pfefer T, Ramella-Roman J, Sapsford K
Sensors (Basel). 2014; 14(7):12127-48.
PMID: 25006996
PMC: 4168472.
DOI: 10.3390/s140712127.
Glucose Measurement by Affinity Sensor and Pulsed Measurements of Fluidic Resistances: Proof of Principle.
Beyer U, Wyss T, Robin F, Heinemann L
J Diabetes Sci Technol. 2014; 8(1):100-108.
PMID: 24876545
PMC: 4454122.
DOI: 10.1177/1932296813516957.
Optimization of a Concanavalin A-based glucose sensor using fluorescence anisotropy.
Cummins B, Garza J, Cote G
Anal Chem. 2013; 85(11):5397-404.
PMID: 23627407
PMC: 3753689.
DOI: 10.1021/ac303689j.
Fluorescence intensity- and lifetime-based glucose sensing using glucose/galactose-binding protein.
Pickup J, Khan F, Zhi Z, Coulter J, Birch D
J Diabetes Sci Technol. 2013; 7(1):62-71.
PMID: 23439161
PMC: 3692217.
DOI: 10.1177/193229681300700108.
Harnessing a nanostructured fluorescence energy transfer sensor for quick detection of extremely small amounts of glucose.
Zhang J, Wang X, Chen L, Li J, Luzak K
J Diabetes Sci Technol. 2013; 7(1):45-52.
PMID: 23439159
PMC: 3692215.
DOI: 10.1177/193229681300700106.
Blood glucose self-monitoring with a long-term subconjunctival glucose sensor.
Muller A, Knuth M, Nikolaus K, Krivanek R, Kuster F, Hasslacher C
J Diabetes Sci Technol. 2013; 7(1):24-34.
PMID: 23439157
PMC: 3692213.
DOI: 10.1177/193229681300700104.
First clinical evaluation of a new percutaneous optical fiber glucose sensor for continuous glucose monitoring in diabetes.
Muller A, Knuth M, Nikolaus K, Krivanek R, Kuster F, Hasslacher C
J Diabetes Sci Technol. 2013; 7(1):13-23.
PMID: 23439156
PMC: 3692212.
DOI: 10.1177/193229681300700103.
First clinical evaluation of a new long-term subconjunctival glucose sensor.
Muller A, Knuth M, Nikolaus K, Herbrechtsmeier P
J Diabetes Sci Technol. 2012; 6(4):875-83.
PMID: 22920814
PMC: 3440159.
DOI: 10.1177/193229681200600419.
Utilizing microfluidics to synthesize polyethylene glycol microbeads for Förster resonance energy transfer based glucose sensing.
Kantak C, Zhu Q, Beyer S, Bansal T, Trau D
Biomicrofluidics. 2012; 6(2):22006-220069.
PMID: 22655010
PMC: 3360714.
DOI: 10.1063/1.3694869.
Technologies for continuous glucose monitoring: current problems and future promises.
Vaddiraju S, Burgess D, Tomazos I, Jain F, Papadimitrakopoulos F
J Diabetes Sci Technol. 2010; 4(6):1540-62.
PMID: 21129353
PMC: 3005068.
DOI: 10.1177/193229681000400632.