The AAPM, through its members, meetings, and its flagship journal Medical Physics, has played an important role in the development and growth of x-ray tomography in the last 50 years. From a spate of early articles in the 1970s characterizing the first commercial computed tomography (CT) scanners through the "slice wars" of the 1990s and 2000s, the history of CT and related techniques such as tomosynthesis can readily be traced through the pages of Medical Physics and the annals of the AAPM and RSNA/AAPM Annual Meetings. In this article, the authors intend to give a brief review of the role of Medical Physics and the AAPM in CT and tomosynthesis imaging over the last few decades.

Citing Articles

Nanoarchitectonics of copper sulfide nanoplating for improvement of computed tomography efficacy of bismuth oxide constructs toward drugless theranostics.

Meng R, Xia H, Zhao Y, Ye Y, Wang S, Chen A Regen Biomater. 2024; 11:rbae128.

PMID: 39600909 PMC: 11593496. DOI: 10.1093/rb/rbae128.


Derivative-Free Iterative One-Step Reconstruction for Multispectral CT.

Prohaszka T, Neumann L, Haltmeier M J Imaging. 2024; 10(5).

PMID: 38786552 PMC: 11122087. DOI: 10.3390/jimaging10050098.


Milestones in CT: Past, Present, and Future.

McCollough C, Rajiah P Radiology. 2023; 309(1):e230803.

PMID: 37847140 PMC: 10644676. DOI: 10.1148/radiol.230803.


Ultrasound Sonosensitizers for Tumor Sonodynamic Therapy and Imaging: A New Direction with Clinical Translation.

Liang Y, Zhang M, Zhang Y, Zhang M Molecules. 2023; 28(18).

PMID: 37764260 PMC: 10537038. DOI: 10.3390/molecules28186484.


Recent developments in X-ray diffraction/scattering computed tomography for materials science.

Omori N, Bobitan A, Vamvakeros A, Beale A, Jacques S Philos Trans A Math Phys Eng Sci. 2023; 381(2259):20220350.

PMID: 37691470 PMC: 10493554. DOI: 10.1098/rsta.2022.0350.


References
1.
Toth T, Ge Z, Daly M . The influence of patient centering on CT dose and image noise. Med Phys. 2007; 34(7):3093-101. DOI: 10.1118/1.2748113. View

2.
Kachelriess M, Schaller S, Kalender W . Advanced single-slice rebinning in cone-beam spiral CT. Med Phys. 2000; 27(4):754-72. DOI: 10.1118/1.598938. View

3.
Bischof C, Ehrhardt J . Modulation transfer function of the EMI CT head scanner. Med Phys. 1977; 4(2):163-7. DOI: 10.1118/1.594305. View

4.
Glover G, Pelc N . Nonlinear partial volume artifacts in x-ray computed tomography. Med Phys. 1980; 7(3):238-48. DOI: 10.1118/1.594678. View

5.
Caon M, Bibbo G, Pattison J, Bhat M . The effect on dose to computed tomography phantoms of varying the theoretical x-ray spectrum: a comparison of four diagnostic x-ray spectrum calculating codes. Med Phys. 1998; 25(6):1021-7. DOI: 10.1118/1.598281. View